C.1
–
Alarm codes for automatic hood type dishwashers
When the alarm
C9
appears, to facilitate fault-finding another parameter providing a more detailed indication has been
introduced.
The parameter is
AL
and is found in the
DBG
family
.
The possible cause of the anomaly can be found (see table below)
according to the value of the parameter
AL
.
With pot washers the cause that generated a
b3
type alarm can also be found.
E.g.: With an automatic hood type the alarm
C 9
appears.
Access the parameter
AL
in the
DBG
family.
AL_8
⇒
the top limit switch could be disconnected or interrupted.
Hood Pot
Washer
S3: FC_DW
S5: FC_UP
(hood CLOSE)
(hood OPEN)
S1: DOOR_CLOSE
AL_1
Appears with hood closed if the top
limit switch (FC_UP) cuts in.
Appears with hood closed, if:
- the bottom limit switch (S3) returns to the rest
position;
- the top limit switch (S5) cuts in;
- S3’’ does not cut in.
AL_2
During lifting, the bottom limit switch (FC_DW)
has not returned to the rest position.
The limit switch must return to the rest position
within a time given by the parameter
t_5
:
a) check that the motor works.
b 3
During the initial lifting phase the bottom limit switch
(S3) must return to the rest position within a time given
by the parameter
t_5
otherwise the alarm
b 3
appears.
- S3 could be stuck.
- S5’ could be disconnected.
On installation this alarm can occur due to incorrect
sequence of the phases: invert the two phases on the
power supply terminal board.
AL_3
-
Appears if during lifting S3’’ does not return to the rest
position within a time
t 1.
AL_4
Appears if the bottom limit switch (FC_DW)
cuts in during lifting.
b 3