WT30M Prog.
034
1. Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 3
Medical line dishwasher with lock door/hood device.
boi 0
Atmospheric boiler.
doo 1
Manual Hood.
dFL 1
Default values for Hood Type models.
trc 0
(for this appliance SOFT START is NOT possible).
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.
LES 0
Detergent level switches not enabled.
UI 8
ACTIVE function disabled
(up to version 3.11 set to
0
)
.
rE 0
Regeneration cycle disabled.
ALr 1
Alarms enabled.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
FAC
Enter into FAC parameter family and change boiler threshold.
bt°C 92
Boiler Temperature Threshold.
bHi 0
Disable boiler high Temperature alarm (
C 2
).
bAJ 0
Boiler Temperature Adjust.
bSt 0
Booster function not needed.
btd 10
During stand-by boiler is kept at lower temperature than Temperature Threshold.
tt°C 65
Tub Temperature Threshold.
tHi 85
Tank high Temperature limit.
5. Modify the cycle parameters:
CY1
Cycle 1 parameters family.
Ln1
3
Long Wash Phase [min]
Sh1
35
Short Wash Phase [s]
pAI 5
Pause [s]
ri1
35
Rinse Phase Duration [s]
dr1
40
Drain [s]
FP1 60
Final Pause at End of Cycle [s].
CY2
Cycle 2 parameters family.
Ln2
6
Long Wash Phase [min]
Sh2
35
Short Wash Phase [s]
pA2 5
Pause [s]
ri2
35
Rinse Phase Duration [s]
dr2
40
Drain [s]
FP2 60
Final Pause at End of Cycle[s].