Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.13/88
CY1
Cycle 1 Parameters
Sym. Parameter
Description
Unit Min Max
Factory
Default
Ln1
Wash Phase Long
[min]
0
20
0
Sh1
Wash Phase Short
[s]
1
60
35
PA1
Pause [s]
0
20
4
Pr1
Pre-rinse Duration
[s]
0
30
0
ri1
Rinse Phase Duration
[s]
10
45
16
cr1
Cold Rinse Phase Duration
[s]
0
50
0
dr1
Drain [s]
0
40
16
FP1
Final Pause at End of Cycle
[s]
0
60
0
CY2
Cycle 2 Parameters
Sym. Parameter
Description
Unit Min Max
Factory
Default
Ln2
Wash Phase Long
[min]
0
20
0
Sh2
Wash Phase Short
[s]
1
60
45
PA2
Pause [s]
0
20
4
Pr2
Pre-rinse Duration
[s]
0
30
0
ri2
Rinse Phase Duration
[s]
10
45
16
cr2
Cold Rinse Phase Duration
[s]
0
50
0
dr2
Drain [s]
0
40
16
FP2
Final Pause at End of Cycle
[s]
0
60
0
CY3
Cycle 3 Parameters
Sym. Parameter
Description
Unit Min Max
Factory
Default
Ln3
Wash Phase Long
[min]
0
20
1
Sh3
Wash Phase Short
[s]
1
60
40
PA3
Pause [s]
0
20
4
Pr3
Pre-rinse Duration
[s]
0
30
0
ri3
Rinse Phase Duration
[s]
10
45
16
cr3
Cold Rinse Phase Duration
[s]
0
50
0
dr3
Drain [s]
0
40
16
FP3
Final Pause at End of Cycle
[s]
0
60
0
bt3
Boiler Temperature Threshold: only for Cycle 3.
This parameter allows having a different rinsing temperature for the
third cycle. Only values above 45°C are allowed.
[°C] 0 95
0
drn
Drain/Cleaning Cycle Parameters
Sym. Parameter
Description
Unit Min Max
Factory
Default
Idr
Initial Drain Phase Duration
[s]
0
240
40
Fdr
Final Drain Phase Duration
[s]
0
240
60