Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.67/88
WT65MEDWS Prog.
043
4. Modify Factory parameters:
FAC
Factory parameters family
bt°C 90
Boiler Temperature Threshold.
bHi 0
Disable boiler high Temperature alarm (
C 2
).
bAJ 0
Boiler Temperature Adjust.
bSt 0
Booster Function.
tHi 85
Tank high Temperature limit.
5. Modify the cycle parameters:
CY1
Cycle 1 parameters family.
Ln1
2
Long Wash Phase [min]
Sh1
32
Short Wash Phase [s]
ri1
35
Rinse Phase Duration [s]
dr1
40
Drain [s]
FP1 15
Final Pause [s]
CY2
Cycle 2 parameters family.
Ln2
3
Long Wash Phase [min]
Sh2
32
Short Wash Phase [s]
ri2
35
Rinse Phase Duration [s]
dr2
40
Drain [s]
FP2 15
Final Pause [s]
CY3
Cycle 3 parameters family.
Ln3
5
Long Wash Phase [min]
Sh3
32
Short Wash Phase [s]
ri3
35
Rinse Phase Duration [s]
dr3
40
Drain [s]
FP3 15
Final Pause [s]
dPA
Set other parameters.
IPA 4
Initial Pause [s]
6. Modify Communication and HACCP parameters:
HCP
Enter into
HCP
parameter family and set the following parameters.
sEr 9
Dishwasher with incorporated continuous water softener.
7. Switch OFF and then switch ON the machine.