Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.35/88
LS5WS / WT4WS TRIPHASE
Prog. 012
1. Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading door type.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.
LES 0
Detergent level switches not enabled.
UI 13
Select user interface for LS5
(up to version 3.11 set to
5
)
.
rE 1
Regeneration cycle enabled.
ALr 1
ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
FAC
Enter into FAC parameter family.
bt°C 83
Boiler Temperature Threshold.
bAJ 2
Boiler Temperature Adjust.
bSt 2
Booster Function.
5. Modify the cycle parameters:
CY3
Cycle 3 parameters family.
Ln3
1
Long Wash Phase [min]
Sh3 40
Short Wash Phase [s]
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
GEn
Enter into GEn parameter family.
dIn 70
Initial Detergent Dosage [s].
rIn 5
Initial Rinse Aid Dosage [s].
8.
Cnt
Counters
rCy 20
Number of cycles allowed before regeneration.
9. Switch OFF and then switch ON the machine.