LS6WS
Prog. 044
1. Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Undercounter like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.
LES 0
Detergent level switches not enabled.
UI
9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE
0
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
ALr 1
Alarms enabled.
3. Modify Communication and HACCP parameters:
HCP
Enter into
HCP
parameter family and set the following parameters.
sEr 9
Dishwasher with incorporated continuous water softener.
4. Switch OFF and then switch ON the machine.
WT38MEDWS Prog.
045
1. Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Under counter like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.
LES 0
Detergent level switches not enabled.
UI 8
ACTIVE function disabled
(up to version 3.11 set to
0
)
.
rE 0
Regeneration cycle disabled (only for dishwashers with non-continuous water softener).
ALr 1
Alarms enabled.
3. Switch OFF and then switch ON the machine.