![Electro Industries/GaugeTech Nexus 1262 User Manual Download Page 99](http://html.mh-extra.com/html/electro-industries-gaugetech/nexus-1262/nexus-1262_user-manual_2379732099.webp)
Doc# E151701 5-1
5: Serial Communication Wiring
Electro
Industries/GaugeTech
™
Powered by Innovation™
5: Serial Communication Wiring
5.1: Communication Overview
The figure below shows serial communication options.
Figure 5.1: Serial Communication
RS232 communication is used to connect a single Nexus® 1262/1272 meter with
another device, such as a computer, RTU or PLC. The link is viable for up to 50 feet
(15.2 m) and is available only through the meter’s Optical port with a communication
interface (Optical port to RS232 converter); see figures 5.2 and 5.3.
RS485 communication allows multiple meters to communicate with another device at
a local or remote site. The I/O modules and external displays use RS485 to communi-
cate with the meter. All RS485 links are viable for up to 4000 feet (1220 m). The
Nexus® Socket meter’s Ports 1 and 4 are two-wire, RS485 connections (up to 115200
baud). Optional Communication Connections for INP200 (10/100BaseT connection) or
INP202 (Combination Modem and Ethernet) are cables with appropriate connectors
(see Chapter 6 and Figure 6.2).
O
p
tical Port
RS232
50 Feet
RS232
50 Feet
RS485
4000 Feet
RS485
4000 Feet
RS232
50 Feet
O
p
tical Port to RS232
Communication Interface
(e.g., A7Z)
RS485/232
Converter
(Unicom 2500)
RS485/232
Converter
(Modem Manager)
-ETER
-ETER
-ETER
4ELEPHONE,INE
&IBER/PTIC,INKOR
2ADIO,INK