ELAD FDM-DUOr
User Manual - Rev. 1.1 - 04/2016
© 2016 ELAD S.r.l. All rights reserved. No part of this document may be reproduced, published, used, disclosed or disseminated in any form or
by any means, electronic, photocopying or otherwise, without prior written permission of ELAD S.r.l.
32
GI
Reads the receiver state
Parameters:
P1 : RIT state
0 : off
1 : on
P2 : always 0
P3 : selected memory index (000-
199)
P4 : always 0
P5 : operating mode (see MD)
P6 : receiver mode (see FR/FT)
P7 : always 0
P8 : always 0000
Set
Read
1
2
3
4
5
6
7
8
9
10
G
I
;
Answer
1
2
3
4
5
6
7
8
9
10
G
I
P1
P2 P3 P3 P3 P4 P5
P6
11
12
13
14
15
16
17
18
19
20
P7 P8
P8
P8 P8
;
GS
Reads or sets the control gain settings
Parameters:
P1
0: auto (AGC)
1: manual
P2 for P1=’0’
0 : slow
1 : medium
2 : fast
P2 for P1=’1’
0 : OFF
1 a 10 : active
Set
1
2
3
4
5
6
7
8
9
10
G
S
P1
P2 P2 P2
;
Read
1
2
3
4
5
6
7
8
9
10
G
S
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
G
S
P1
P2 P2 P2
;
IF
Retrieves the receiver status
Parameters:
P1: Frequency 11 digit
P2: 5 spaces
P3: RIT value in tens of hertz
P4: RIT state
0: OFF
1: ON
P5: Always 0
P6/P7: Memory ch. Number 0-199
P8: Always 0
P9: Operating Mode (See MD)
P10: See FR/FT
P11: Always 0
P12: Always 0
P13: Always 0
P14: Always 0
P15: Space
Set
Read
1
2
3
4
5
6
7
8
9
10
I
F
;
Answer
1
2
3
4
5
6
7
8
9
10
I
F
P1
P1
P1
P1
P1
P1 P1 P1
11
12
13
14
15
16
17
18
19
20
P1
P1
P1
P2
P2
P2
P2
P2 P3 P3
21
22
23
24
25
26
27
28
29
30
P3
P3
P3
P4
P5
P6
P7
P7 P8 P9
31
32
33
34
35
36
37
38
39
40
P10 P11 P12 P13 P14 P14 P15
;