![EHRLE HS 1040 Series Operating Instruction Download Page 56](http://html1.mh-extra.com/html/ehrle/hs-1040-series/hs-1040-series_operating-instruction_2368757056.webp)
Hochdruck-Reinigungs-Systeme High-Pressure-Systems
119
• Draw out the oil of the high pressure pump (environment protection).
• Fill up oil to upper mark at the oil dipstick in the gear box.
3.2.7 Descaling the High Pressure Cleaner
If there is any scale build-up in the High Pressure Cleaner the high pressure
pipe resistance increases and the unloader valve conveys water into the pump
circle.
The high pressure pipe resistance can be checked by operating the High Pres-
sure Cleaner from the most distant wash place by checking the operating pres-
sure with the high pressure hose disconnected. If there are more high pressu-
re pipes, every high pressure pipe must be checked separately. If the high
pressure pipe resistance exceeds 25 bar, descale the high pressure cleaner.
Pay careful attention on the directions for use and accident
prevention regulations, above all VBG 1, §§ 4, 14, -4 -47 (e.g. the
wearing of gloves and protective goggles).
In accordance with the statutory regulations, use only approved
boiler cleaning compounds for descaling.
The resulting gases of the descaling process are in ammable. Do
not smoke during descaling process. Take care to provide
adequate air ventilation (if required wear respiratory protection).
For descaling proceed as follows:
• Close water supply shut off valve.
• Operate the High Pressure Cleaner until the oat container is empty.
• Fill up the oat container with approx. 3 l descaling acid.
• Open the water supply shut off valve.
• Remove the spray nozzle and descale separately.
• Insert the spray wand into a empty container with a capacity of approximately
20 l and commission the High Pressure Cleaner by pulled trigger gun.
Operate the High Pressure Cleaner until descaling acid emerges from spray
lance. Stop the device for 20 minutes.
• Operate the High Pressure Cleaner until clear water is emerging from spray
wand. Check the system pressure. The pipe resistance pressure must have
the same value as the recorded value in the factory test report. Otherwise
repeat the descaling process. The high pressure pipe system could also be
descaled.
WARNING
Summary of Contents for HS 1040 Series
Page 62: ...Hochdruck Reinigungs Systeme High Pressure Systems 125...
Page 75: ...Hochdruck Reinigungs Systeme High Pressure Systems 138...
Page 77: ...Hochdruck Reinigungs Systeme High Pressure Systems 140...
Page 79: ...Hochdruck Reinigungs Systeme High Pressure Systems 142...
Page 81: ...Hochdruck Reinigungs Systeme High Pressure Systems 144...
Page 82: ...Hochdruck Reinigungs Systeme High Pressure Systems 145 6 4 Sicherheitsgruppe Safety parts...
Page 83: ...Hochdruck Reinigungs Systeme High Pressure Systems 146...
Page 85: ...Hochdruck Reinigungs Systeme High Pressure Systems 148...
Page 87: ...Hochdruck Reinigungs Systeme High Pressure Systems 150...
Page 88: ...Hochdruck Reinigungs Systeme High Pressure Systems 151 6 6 Druckregelventil Unloader valve...
Page 89: ...Hochdruck Reinigungs Systeme High Pressure Systems 152...
Page 91: ...Hochdruck Reinigungs Systeme High Pressure Systems 154...
Page 93: ...Hochdruck Reinigungs Systeme High Pressure Systems 156...
Page 94: ...Hochdruck Reinigungs Systeme High Pressure Systems 157 6 9 Pumpe HS 1040 Pump HS 1040...
Page 95: ...Hochdruck Reinigungs Systeme High Pressure Systems 158...
Page 97: ...Hochdruck Reinigungs Systeme High Pressure Systems 160...
Page 98: ...Hochdruck Reinigungs Systeme High Pressure Systems 161 6 11 Pumpe HS 1240 Pump HS 1240...
Page 99: ...Hochdruck Reinigungs Systeme High Pressure Systems 162...
Page 100: ...Hochdruck Reinigungs Systeme High Pressure Systems 163 6 12 Pumpe HSE 800 Pump HSE 800...
Page 101: ...Hochdruck Reinigungs Systeme High Pressure Systems 164...
Page 102: ...Hochdruck Reinigungs Systeme High Pressure Systems 165...
Page 105: ...Hochdruck Reinigungs Systeme High Pressure Systems 168...
Page 107: ...Hochdruck Reinigungs Systeme High Pressure Systems 170...
Page 109: ...Hochdruck Reinigungs Systeme High Pressure Systems 172...
Page 111: ...Hochdruck Reinigungs Systeme High Pressure Systems 174...
Page 113: ...Hochdruck Reinigungs Systeme High Pressure Systems 176...
Page 115: ...Hochdruck Reinigungs Systeme High Pressure Systems 178 Notizen...
Page 116: ...Hochdruck Reinigungs Systeme High Pressure Systems 179...