Menu 6-3 Cooling
COOLING POS: XXXXX
Entry
Default
corr.off to XX K
Correction offset for pressure loss in suction line
IMPORTANT:
in stand alone operation must be set to ”--”!
--, 0..20
2 K
Cont Cool Mon. XX m
Continuous run monitoring
--, 0..15
0 min
EnablingRel XXX
Switching to “Enable Operation“:
OFF Opening degree is transmitted via the solid state
relay (SSR) ON The two SSRs are no longer clocking,
they are switched on if the case controller requires
refrigeration, i.e. switched off again if no refrigeration is
required.
↑, ↓
(ON/OFF)
OFF
Menu 6-4 Language
Selection is made according to entry. Checkmark shows current setting.
LANGUAGE POS: XXXXX
Entry
Default
Deutsch D
English GB
Francais F
Espanyol ESP
Finnish FIN
Cesky CZ