Menu 2-6 Fans
Controller type UA 131 E:
with fan control Menus 2-6 / 2-6-1 / 2-6-2 are only show when the case controller is configured to UA 131 with
fan control (further details in the chapter
Installation and Startup of UA 4xx E
):
FANS POS: XXXXX
1 Zone 1+2
Move to menu 2-6-1
2 Zone 1+2 Altern.
Move to menu 2-6-2; shown only when setpoint toggle is activated (Menu 3-3)
Menu 2-6-1 Zone 1+2
FANS POS: XXXXX
Entry
Default
Fans Start XXX °C
Fan start temperature setpoint
--, -20..20
– °C
Menu 2-6-2 Zone 1+2 Toggle
FANS A POS: XXXXX
Entry
Default
Fans Start XXX °C
Fan start temperature setpoint
--, -20..20
– °C
Controller type UA 131 E LS:
with advanced fan control Menu 2-6 only shown when the case controller is configured to UA 131 LS with
advanced
fan control (further details in the chapter
Installation and Startup of UA 4xx E
FANS POS: XXXXX
1 Zone 1+2
Move to menu 2-6-1
Menu 2-6-1 Zone 1+2
FANS POS: XXXXX
Entry
Default
Op.mode: XXXXXXXXXXXX
Possible operating modes:
Continuous operation, Forerun, Overrun
CONTINUOUS
FORERUN
OVERRUN
DEL.A.DEFR.
CONTINUOUS
Fans Start
Continuous operation mode: not relevant
Forerun mode: not relevant
Overrun mode: Fan on by undershoot of
temperature at
evaporator sensor
Delay after defrost mode: Fan on by
undershoot of temperature
at evaporator sensor
--, -20..20
– °C
Fan hightemp.
Continuous operation mode: not relevant
Forerun mode: fan on when temperature at
evaporator
sensor exceeded
Overrun mode: fan off when temperature at
evaporator
sensor exceeded
Delay after defrost mode: not relevant
-30..30
5 °C
Summary of Contents for Case Controller UA 4 E Series
Page 23: ...Firmware V3 13 21 04 2021 23 466 For more details see chapter Operation UA 4xx E ...
Page 135: ...Firmware V3 13 21 04 2021 135 466 Exit the menu by tapping the ESC button twice ...
Page 158: ...Firmware V3 13 21 04 2021 158 466 Anschlussbild UA 401 E CC One zode controller ...
Page 207: ...Firmware V3 13 21 04 2021 207 466 ...
Page 277: ...Firmware V3 13 21 04 2021 277 466 ...