Firmware V3.13
21.04.2021
165/466
Controller type
D42/D41
D32/D31
D22/D21
D12/D11
Case controller
UA 121 E
UA 131 E
UA 131 E LS
External alarm
1) 2)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Manual shutdown All
1)
or
Manual shutdown Z1 /
Manual shutdown Z2
Toggle setpoint
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2
Defrost
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Case controller
UA 141 E
External alarm
1) 2)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Pane button
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2
Toggle setpoint
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2
Shutdown button
Defrost
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Cold room controller
UR 141 NE
UR 141 TE
External alarm
1) 2)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Cold room door 1
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2
Toggle setpoint
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Cold room door 2
Defrost
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Only UA 410 E AC
Subcooler controller
UK 100 E
External alarm
1) 2)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Manual shutdown All
1)
or
Manual shutdown Z1 /
Manual shutdown Z2
Toggle setpoint
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2
Defrost
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Cascade controller
KR 160 E
External alarm
1) 2)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
Manual shutdown All
1)
or
Manual shutdown Z1 /
Manual shutdown Z2
Toggle setpoint
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2
Defrost
1)
or
Manual shutdown All /
Manual shutdown Z1 /
Manual shutdown Z2 /
Toggle setpoint
1)
Factory setting
2)
Freely configurable alarm text - factory setting is “CO2 Alarm”
If a 230 V AC voltage is present at a digital input, the associated red LED lights. For details see
Summary of Contents for Case Controller UA 4 E Series
Page 23: ...Firmware V3 13 21 04 2021 23 466 For more details see chapter Operation UA 4xx E ...
Page 135: ...Firmware V3 13 21 04 2021 135 466 Exit the menu by tapping the ESC button twice ...
Page 158: ...Firmware V3 13 21 04 2021 158 466 Anschlussbild UA 401 E CC One zode controller ...
Page 207: ...Firmware V3 13 21 04 2021 207 466 ...
Page 277: ...Firmware V3 13 21 04 2021 277 466 ...