142/466
7.
8.
9.
Restore power to the case controller and refrigeration point. Refrigeration point operates again.
Controller in the CAN bus system
: With unchanged configuration of the system centre / store computer,
the controller is automatically detected again via the CAN bus; date, time and automatic summer / winter
time changeover are set automatically via the central time synchronisation.
Controller in standalone operation
: The setting of date, time and automatic summer / winter time
changeover is required for the data archiving (Menu 3-1).
In the case of
Restart - restart of the controller
, (error) messages are output. These must be checked /
acknowledged in the higher level controller or using the set-up unit!
DANGER
Warning about dangerous electrical voltage! Danger of electric shock!
A voltage of 230 V AC
can be present on some connectors.