30 DC motor driver module XN-322-1DCD-B35
30.4 Technical data
XN300 slice modules
06/16 MN050002 EN
www.eaton.com
249
30.4 Technical data
30.4.1 DC motor driver
The rated uninterrupted current for the motor should not exceed the speci-
fied value of 3.5 A continuously.
This also applies to the motor's deceleration and startup when the motor is
repeatedly switched off and on.
The maximum let-through energy during motor startup is defined by integral
∫
I
2
dt. The I
2
T value is the integral of the square of the current over a speci-
fied period of time. It is also a measurement of the maximum energy that the
load output can deliver.
Quantity
1
Supply voltage
12 – 30 VDC
Rated operational current I
N
0 – 3.5 A
Operating mode
S3 / 50% (50% intermittent duty) with a maximum duty factor of 1.5 min
Load peak inrush current
Maximum I
2
t-value = 16A
2
s
Current Metering
10 Bit
Short-circuit proof
No
status display
1x LED (green)