7RXFK3DQHO/RFNRXW0RGH&RPPDQG^)7/0`5HPRWH
The Touch Panel Lockout Mode command controls the Touch Panel Lockout Mode, which
allows the host to lock out user input from the touch panel. This command does not affect the
optional keyboard.
•
When the Touch Panel Lockout Mode is reset, input is allowed from the touch panel. (The
touch panel is unlocked.)
•
When the Touch Panel Lockout Mode is set, input is not allowed from the touch panel. (The
touch panel is locked.)
If the TCS receives a Read Touchkey Status command when the Touch Panel Lockout Mode is
set, the TCS reports the touchkey number 000 to indicate no inputs have occurred. (The format of
this report is described under Read Touchkey Status Command, earlier in this chapter.)
If the user enters the Setup Screen (either by pressing the Set Up switch or the Set Up key) when
the Touch Panel Lockout Mode is set, the touch panel is temporarily unlocked. When the user
exits the Setup Screen or enters the Communication Monitor, the touch panel reverts to the
locked state.
If the user is pressing a touchkey while the Touch Lock-out Mode is in the process of being set,
and the touchkey has begun auto-repeating, the touchkey will stop auto-repeating.
'()$8/7
Reset (unlocked).
23(5$72586$*(
None. (This is a remote command only.)
+26786$*(
<ESC>[>2l
Resets Touch Panel Lockout Mode (unlocks the touch panel). (The terminator for the reset
command is the letter "l," ASCII 6C hex.)
<ESC>[>2h
Sets Touch Panel Lockout Mode (locks the touch panel).