Temperature setting
- Select screed section by pressing but-
ton.
- Depending on the desired tempera-
ture change, press button (3) or (4).
- The current nominal temperature is
shown first. Adjustment in the corre-
sponding direction is undertaken after
1.5 seconds.
A
When changing the temperature setting,
4 dots light up on the display.
4.8
Fault messages
When a fault occurs, the small red lamp
(5a, 6a, 7a, 8a) for the relevant screed
section lights up and the corresponding
heating system is switched off.
The fault code and faulty screed section
are shown on the display.
If several faults occur, the last fault to oc-
cur is shown on the display; the faults
which occurred previously can be called
up on the display by pressing the rele-
vant buttons.
To delete the fault display, the fault first
has to be rectified and then the relevant
section button pressed until the small
red lamp goes out.
Fault codes
A
Heating system remains in operation as long as at least one temperature sensor func-
tions.
If the temperature sensor of e.g. a middle section fails, the heating system is switched
to the other middle section's sensor.
A similar function is provided for the extendable parts.
Fault code
Meaning
50
- Defective temperature sensor
STC20002.bmp
3
4
2
STC20002.bmp
6a
5a
8a
7a
Summary of Contents for Svedala Demag EB 34 Series
Page 2: ...VALUE QUALITY THE ORIGINAL Your Authorized Dynapac Dealer...
Page 14: ......
Page 16: ......
Page 70: ......
Page 87: ...F 17 F_EB34_VB340_05 08_GB fm 17 18 11 Test certificates 11 1 Electric screed heating system...
Page 88: ......