D 15
D_E3
4_VB340_
05.
08_G
B.
fm
15-
2
6
- 01.
01.
07
Item
Designation
1
EMERGENCY STOP button
2
Check button for insulation monitoring and insulation error pilot lamp
3
Insulation monitoring reset button
4
Generator telltale lamp
5
Heating ON/OFF
6
Circuit breaker for heating section 1
7
Circuit breaker for heating section 2
8
Circuit breaker for heating section 3
9
Circuit breaker for heating section 4
10
Heating section 1 telltale lamp
11
Heating section 2 telltale lamp
12
Heating section 2 telltale lamp
13
Heating section 4 telltale lamp
14
Headlights On / Off (sockets 25+26)
15
Headlights On / Off (sockets 27+28)
16
Circuit breaker for sockets 25+26
17
Circuit breaker for sockets 27+28
18
Socket (heating) for main screed on left
19
Socket (heating) for main screed on right
20
Socket (heating) for extendable part on left
21
Socket (heating) for extendable part on right
22
Circuit breaker for generator telltale lamp
23
Main fuse and EMERGENCY STOP trigger
24
Control and monitoring unit STC2000
25
230 volt socket for additional headlight
26
230 volt socket for additional headlight
27
230 volt socket for additional headlight
28
230 volt socket for additional headlight
Summary of Contents for Svedala Demag EB 34 Series
Page 2: ...VALUE QUALITY THE ORIGINAL Your Authorized Dynapac Dealer...
Page 14: ......
Page 16: ......
Page 70: ......
Page 87: ...F 17 F_EB34_VB340_05 08_GB fm 17 18 11 Test certificates 11 1 Electric screed heating system...
Page 88: ......