SapIP – IRT Instruction Manual 1/23/2017
Page 27
Dynamax, Inc.
o
Note: The delay previously mentioned is subtracted from 200 milliseconds and the remainder is
used for an additional delay. This makes the total delay exactly 200 milliseconds.
6.
Output Analog DC Telemetry Signal
-
At the same timing interval as the radio outputs, an Analog DC (ADC) telemetry signal will be
updated. The conversion formula from the voltage output is:
-
T = V
o
/0.01 - 40.0 (T is in degrees C).
Voltage
Range 0 – 1.6 V
-
An EEPROM switch determines whether the ADC telemetry signal is used. If is not set, the DAC
is left asleep. The unit either does radio transmit and ADC, or just one output.
-
(Whichever combination is set by the two EEPROM variables: DAC_OUTPUT and
RADIO_OUTPUT).
7.
Repeat sequence
-
Code jumps back to “Read Temperature” above. After the data is taken, formatted, and
transmitted.