SapIP – IRT Instruction Manual 1/23/2017
Page 10
Dynamax, Inc.
3.4
Digimesh Range with Analog Signal SapIP-IRT-AD (SapIP- Agrisensors Network)
3.4.1
With the Digimesh SapIP-Network, one may attach 6 IRT-AD sensors to one network node.
3.4.2
Each analog signal node is converted to digital, transmitted, and individually converted to
temperature at the Agrisensor.net customer Ranch Page.
3.4.3
Canopy temperatures may also be converted to Growing degree days, Crop Water Stress
Index (CWSI) , or to Degrees Above Non Stressed Plants (DANS). CWSI requires a SapIP
weather node. The canopy temperature and tree trunk is converted to chill hours and are
best used for freeze warnings.
4.
Antenna Range
4.1
Zigbee Specifications 2.4 GHz Range. Dynamax uses a high power 2.4 transmitter.
4.1.1
Range 1600 feet (500 meters): 5 to 7 dBi antenna omnidirectional - (high gain). High gain
antennas are included with coordinators and Routers. Each high gain antenna is sealed form
water and is more sensitive when it’s raining. Part Number kit is SPIP-ACC24-EW.
4.1.2
Range 300-500 ft ( 100-150 meters): 7 dbi antenna omnidirectional – with spark gap
protection, and grounding. Part no is SPIP-ACC24, and is an exposed antenna.
4.1.3
Range 150 feet (50 meters): 1 to 1.5 dBi antenna omnidirectional - (low gain, rubber duck
style). Sealed water-proof rubber duck are supplied by Dynamax (Most Wi-Fi antennas are
not water proof). Part no is SPIP-IRTANT24.
4.1.4
Range over 500 meters: Dynamax supplies directional antennas, which can extend range 3-
4x.
4.1.5
All Ranges are in clear air - line of sight (LOS). With vegetation, the signal should be 1-2
meters above the canopy (3-6 ft). Rain and wet canopy absorb 2.4 Ghz signals, and the
signal is absorbed on a wet antenna. For increased LOS range use the DigiMesh 900 Mhz.
See Section 3.3 or 3.4 for high range.
5.
Power SAPIP-IRT-ZB Battery and Solar Panel
5.1
Battery Specifications –
Rechargeable 4 NIMH batteries included. Typical current 2000 mAh, 4.8 V.
(Typical battery pack is 4.8 V nominal, 5.2 V operational charged)
Maximum battery voltage – 6.2 V during charging
Minimum battery operations – 4.2 V
Operational measurements and response suspended at below 3.8V,
Until minimum voltage is restored (4.2 V).
Only battery recharge will occur below 3.8 V.