![Dürkopp Adler M-TYPE H867 Service Manual Download Page 56](http://html1.mh-extra.com/html/durkopp-adler/m-type-h867/m-type-h867_service-manual_2542304056.webp)
Setting the spool housing lifter
54
Service manual H867 Version 00.0 - 08/2013
12.1 Setting the lifting gap
Sequence
Always check the width of the lifting gap after making changes to the nee-
dle thread size.
The correct width of the lifting gap depends on the size of the needle
thread.
Correct setting
The needle thread slides through unobstructed between the nose of the
spool housing and the recess in the throat plate.
Cover
• Tilt the upper section backwards
4.4.1 Access to the machine bottom section
• Throat plate slide
4.4.5 Opening and closing the throat plate slide
Figure 41: Setting the lifting gap
Setting steps
1. Loosen the cover screw (3).
2. Push the cover (2) downwards.
3. Loosen the setscrew (1).
4. Set the spool housing lifter such that the gap between the nose of the
spool housing and the recess in the throat plate is just big enough to
allow the needle thread to slip through without a problem.
Important:
The gap must not be so big that the middle part of the hook
swings to and fro, hitting the recess in the throat plate.
5. Tighten the setscrew (1).
6. Push the cover (2) upwards.
7. Tighten the cover screw (3).
Risk of injury
Switch off the sewing machine before setting the width of the
lifting gap.
WARNING
4
1
2
3
(1) - Setscrew
(2) - Cover
(3) - Cover screw
(4) - Spool housing lifter