OP000471
4-27
Inspection, Maintenance and Adjustment
Check Oil Level in Travel Reduction
Device (One on Each Side of Unit)
1.
Make sure that the machine is on firm, level ground.
2.
Rotate the track until ports (1 thru 3, Figure 41) are in
their proper positions as shown.
3.
Loosen fill plug (3, Figure 41) slightly to allow
pressurized air to escape.
4.
Remove oil level plug (1, Figure 41).
5.
Check oil level. The oil should be near the bottom of
the level plug opening.
6.
Add oil through the fill plug (3, Figure 41) opening, if
necessary.
7.
Clean and install oil level and fill plugs (1 and 3,
Figure 41).
8.
Repeat this procedure on the other travel reduction
device.
Change Oil in Travel Reduction Device
(One on Each Side of Unit) (After
First 250 Hours)
NOTE:
Drain and refill oil after first 250 hours of operation or
rebuild, and every 1,000 hours thereafter (See page
4-32).
Replace Hydraulic Oil Return Filter
(After First 250 Hours)
NOTE:
Replace hydraulic oil return filter after first 250 hours
of operation or rebuild, then every 1,000 hours
thereafter (See page 4-31).
Figure 41
1
3
2
FG007685
WARNING!
The gear oil is very hot after the machine has been
operating. Shut all systems down and allow them to
cool. Before fully removing any motor case inspection
port plug, etc., loosen the plug slightly to allow
pressurized air to escape.