OP000471
4-31
Inspection, Maintenance and Adjustment
1,000 HOUR / 6 MONTH SERVICE
Perform All Daily, 50, 250 and 500 Hour
Service Checks
Replace Hydraulic Oil Return Filter
NOTE:
Change hydraulic oil return filter after first 250 hours
of operation or rebuild, and every 1,000 hours
thereafter.
1.
Park machine on firm, level ground. Lower the front
attachment to the ground and shut down engine.
2.
Loosen the breather cap (1, Figure 45) slightly to
release the internal pressure.
3.
Remove bolts (2, Figure 45) and oil filter set (3).
4.
Remove bolts (5) and filter locker.
5.
Discard the filter (7). Install new filter.
6.
Clean the oil filter set (3) and O-ring (4, Figure 45).
7.
Install all parts in reverse order.
8.
Run engine for ten minutes at low idle to purge air
from circuit.
9.
Check level in hydraulic oil tank (See page 4-13). Add
oil if necessary.
3
2
4
1
FG008080
Figure 45
WARNING!
The hydraulic oil will be hot after normal machine
operation. Allow the system to cool before attempting to
service any of the hydraulic components.
The hydraulic tank is pressurized. Loosen the hydraulic
breather cap slightly to allow the pressurized air to vent.
After the pressure has been released, it is safe to
remove either the fill cap or service covers or drain
water from the tank.
Figure 46
5
6
7
FG008081
IMPORTANT
Make sure to clean any dirt or water from the top of the
hydraulic tank, especially around the fill port and filter
ports.
Summary of Contents for DX35Z
Page 2: ......
Page 6: ...Table of Contents K1025196E IV Index 8 1 ...
Page 60: ...OP000468 Safety 1 54 ...
Page 90: ...OP000469 Operating Controls 2 30 ...
Page 132: ...OP000470 Operation 3 42 ...