OP000470
Operation
3-8
If the batteries are drained during starting procedures, jump start
engine using auxiliary or booster batteries according to the
following procedure:
Connecting the Booster Battery
1.
Shut down engine of the machine on which booster battery
is mounted (c, Figure 11).
2.
Connect one end of red cable (a, Figure 11) to the
positive (+) terminal of the machine battery, and the
other end to the positive (+) terminal of the booster
battery (c, Figure 11).
3.
Connect one end of black cable (b, Figure 11) to the
negative (-) terminal of the booster battery, and then
make ground connection to the upper frame of the
machine (e, Figure 11) to be started with the other end
of black (-) cable (b, Figure 11). When making the last
connection to upper frame, be sure to connect the
cable end as far away from the machine battery as
possible. DO NOT CONNECT DIRECTLY TO THE
NEGATIVE BATTERY TERMINAL.
4.
Start the engine.
Disconnecting the Booster Battery
1.
Disconnect black negative (-) cable (b, Figure 11) from
the machine frame first.
2.
Disconnect the other end of black negative (-) cable (b,
Figure 11) from the booster battery.
3.
Disconnect red positive (+) cable (a, Figure 11) from
the booster battery.
4.
Disconnect red positive (+) cable (a, Figure 11) from
the machine battery.
IMPORTANT
The machine has a 12V (-) negative ground electrical
system. Use the same capacity 12V booster batteries when
jump starting engine.
b
a
Red
Black
c
d
e
AXO0510L
Figure 11