OP000470
Operation
3-32
Hydraulic Oil and Filter Service Intervals
When using a hydraulic breaker, the viscosity breakdown and
contamination of hydraulic oil is faster because the work
condition is more severe than during normal digging work. To
prevent the hydraulic components (especially pump) from
having a shortened life cycle, replace the hydraulic oil and main
hydraulic oil return filter using the following schedule.
NOTE:
The replacement intervals of hydraulic oil and filter
depend upon the amount of time the hydraulic
breaker is being used. These intervals should be
followed as opposed to regularly scheduled
maintenance.
Attachment
Operation Rate
Hydraulic Oil
Filter
Bucket Work
100%
2,000 Hours
250 Hours (First Replacement)
1,000 Hours (After First Replacement)
Hydraulic Breaker
Work
100%
500 Hours
100 Hours
* These service intervals only apply, when a genuine
DOOSAN
oil and filter are used. If any other
brands are used, the guaranteed changed interval should be reduced in half.
MACHINE OPERATING HOURS
2000
1500
1000
500
0
20
40
60
80
100
BREAKER OPTION RA
TE (%)
(After First Replacement)
FILTER
FILTER
(First Replacement)
HYDRAULIC OIL
1658
1400
1196
1028
893
782
692
614
551
105
110
130
150
180
210
250
300
3705
206
175
156
128
137
112
119
106
FG007618
Figure 76