Assembling the device
88
Connecting the Access Manager or Access Manager Terminal
(control unit) of the ENiQ module reader or module reader
terminal to the network and the power supply
ATTENTION!
Material damage can be caused by incorrect connection.
Observe the terminal allocation of the devices.
Ensure that the device is connected in line with the wiring
diagram.
Ensure that there is a suitable power supply.
Set the DIP switches to the appropriate position.
Make sure that the maximum cable resistance and maximum cable length
are not exceeded.
ENiQ Module Reader/Module Reader Terminal control unit, potential-free
switch/button, control unit inputs
Max. cable resistance
<10 Ω
Max. cable length
<20 m
Actuators (door openers, etc.) are controlled by the device by means of a
potential-free relay changeover contact. One potential-free opener contact (C-
Ö) and one potential-free closer contact (C-S) are available.
You can connect potential-free switches or buttons to the inputs. These inputs
must be occupied according to the stored configuration. The standard
configuration is factory-set. Input IN1 is the door contact (opener) and input
IN2 the release button (closer).
Terminal allocation of the Access Manager Compact or Access Manager
Terminal (control unit)
ATTENTION!
Material damage can be caused by incorrect connection.
Observe the terminal allocation of the devices.
Ensure that the device is connected in line with the wiring
diagram.
The terminals must be allocated in line with the diagram below: