Programming and management with software or app
113
The following status messages and signal sequences apply exclusively
to the ITT devices.
Locking medium is authorised on the Access Manager ITT (conventional and
Data on Card):
Possibility A:
The locking medium (conventional or Data on Card) is authorised and does
not participate in the data update:
The changeover contact is activated. In this process, the lower LED lights up
green for the duration of the set contact hold time and you will hear an audible
signal.
Possibility B:
The locking medium (Data on Card) is authorised, participates in the data
update and the programming of the data has worked: The programming of the
updated data occurs first of all. The upper LED (ELS) or the four LEDs (ENiQ)
light up purple during programming.
The changeover contact is subsequently activated. In this process, the lower
LED lights up green for the duration of the set contact hold time and you will
hear an audible signal.
Possibility C:
The locking medium (Data on Card) is authorised, participates in the data
update and the data update has not worked: If there is an error during
programming of the data or programming is cancelled, LEDs will flash red
briefly three times and you will hear three audible signals where appropriate.
In this case, the changeover contact is subsequently not activated.