![Doka Platform SCP Original Operating Instructions / Instructions For Assembly And Use Download Page 121](http://html.mh-extra.com/html/doka/platform-scp/platform-scp_original-operating-instructions-instructions-for-assembly-and-use_2516579121.webp)
Original Operating Instructions
Platform SCP
Structural design – Lifting unit attached on one side
121
999805802 - 03/2016
Service loads
+1 ... working and storage platform
0 ... working platform
-1, -2 ... suspended platform
The permitted live load of the system as a whole is
determined separately for all the operational phases
of each project.
▪
Working situation
▪
Lifting operation
▪
Storm winds
A
max. 300kg/m
2
- level +1
B
max. 150kg/m
2
- levels 0, -1, -2
98058-406-01
A
B
B
B
B
B
B
-1
-2
+1
0
Max. lifting force per cylinder: 400
kN
☞
During lifting, it is not permissible for the sum of
the vertical loads in the area of influence of any
one hydraulic cylinder to exceed 400 kN.