42
END
- Press the select key directly below
END
to stop the Walk Test. When the
Walk Test ends or a 20 minute time-out expires, a final Sensor Reset occurs. The
System Test End message is sent to the receiver along with Verify and Fail
messages for each zone under test. Faulted zones are then displayed on the
keypad.
Failed Zones Display
For each zone that did not trip (failed) at least once during the Walk Test, the
keypad displays the zone name and number and buzzes for one second. Press the
COMMAND key to display the next failed zone.
Local Printer for Walk Test
When the Walk Test is completed, a Verify or Fail message for each zone tested is
printed to the local printer. You must have a 462P Interface card to print Walk
Tests. Select
YES
for Zone under Printer Reports to enable the XR200 to print the
Walk Test.
17.4 690 Series Keypads Speaker Operation
When using the 690, 790, 791, or 793 Security Command LCD Keypads or the 630F Remote Fire Command Center, the
panel provides distinct speaker tones from the keypad for Fire, Burglary, Zone Monitor, and Prewarn events. The list
below details the conditions under which the speaker is turned on and off for each event.
Fire
On
- Fire zone alarm and Bell Output or Fire Bell Output is ON.
Off
- Alarm Silence.
Burglary
On
- Burglary zone alarm and Bell Output or Burglary Bell Output is ON.
Off
- Alarm Silence.
Zone Monitor
On
- One time only when a monitored zone is tripped.
Off
- After one tone.
Prewarn
On
- During Entry Delay.
Off
- When Entry Delay expires.
17.5 Pager Direct Specifications
The XR200 communicates in a full-duplex mode with a Glenayre alphanumeric pager terminal. The terminal modem
must accept the following parameters:
• 300 bps Bell 103 protocol
• Carrier detect response time = 300ms
• Delay between lost carrier and hang-up = 12.0 seconds
The following alphanumeric pager specifications must also be met in order for the pager to receive Pager Direct
reports:
Glenayre Electronics GL3000 protocol:
• 300 Baud
• 7 Bits Data
• 1 Stop Bit
• Even Parity
SOUTH LOBBY
ZONE: 10 - FAIL
17 - APPENDIX