Digital Monitoring Products
XR200/XR2400F Programming Guide
38
15.1
Stop
At the
STOP
prompt, pressing any Select key allows you to exit the Programmer
function of the panel. When selected, the panel performs an internal reset and
exits the programmer.
The STOP routine causes the following conditions to occur:
• All areas in all partitions are DISARMED
• All zones in all partitions are DISARMED
• The panel's Status List is CLEARED
During the reset, all keypad displays are momentarily blank for two seconds.
After the reset, the programming function is terminated and the keypads return to
the status list display.
Missing LX-Bus™ Modules Displayed
The Programmer includes a feature following the STOP routine that displays the
name of any
programmed
LX-Bus module not currently connected to the panel.
For example, if you had enabled any of the wireless options and not yet installed a
472 Inovonic
S
900MHz Card, after the STOP routine the panel would display
NO
WIRELESS CARD
. This is a helpful reminder to install the card. This feature can
also be a troubleshooting tool that could indicate a problem if you
had
installed
the card and still saw this message displayed. The following list shows the
different messages and their associated LX-Bus cards.
Keypad Display
Missing Card
NO LXBUS CARD
481 LX-Bus™ Expansion Card
NO WIRELESS CARD
472 Inovonic
S
900MHz Card
NO PRINTER CARD
462P Printer Interface Card
NO HOST CARD
462N Network Interface Card
(with HOST communication selected)
The above messages clear automatically from the keypad after a few moments.
16.1
Set Lockout Code
Pressing COMMAND at the
STOP
prompt displays
SET LOCKOUT CODE.
This allows
you to program a code that will then be required to gain access to the panel's
internal Programmer through the keypad. You can change this code at any time to
any combination of numbers from 3 to 5 digits long. Leading zeros do not have to
be entered when using the lockout code. Initializing the panel will not clear a
Lockout Code. Lockout Codes can be changed through Remote Link.
Once you have changed the code, it is important to write it down somewhere and
store it in a safe place. Lost Lockout Codes require the panel to be sent back to
DMP for repair. You may cancel a Lockout Code by entering 00000 at the Set
Lockout Code command.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
STOP
SET LOCKOUT CODE
15 - STOP
16 - SET LOCKOUT CODE