XR200/XR2400F Programming Guide
Digital Monitoring Products
17
6.1
System Reports
This section allows you to select specific system reports the panel sends to the
receiver.
6.2
Abort Report
YES
allows the panel to send an alarm abort report to the receiver any time an
area is disarmed after an alarm report has been sent and the Bell Cutoff Time has
not expired. No alarmed zones can still be armed. If the communication type is
set to DD, a
Warning: Alarm Bell Silenced
report is also sent if the alarm bell is
silenced by a user.
Abort reports are also sent when the system is disarmed during Transmit Delay and
the Bell Output Timer is active.
Note
: Abort reports will not be sent for Fire zones, Fire Verify, or Supervisory type
zones.
6.3
Restoral Reports
This option allows you to control when and if a zone restoral report is sent to the
central station receiver. Press a Select key to display the following options:
NO
- Disables the zone restoral report option. Zones continue to operate normally
but do not send restoral reports to the receiver.
YES
- Enables the zone restoral report option. Zone restorals are sent whenever a
zone restores from a trouble or alarm condition.
DISARM
- This option causes the panel to send restoral reports for a non-24-hour
zone whenever a zone that has restored from a trouble or alarm condition is
disarmed. All 24-hour zones send restoral reports as they restore.
6.4
Bypass Reports
YES
allows the panel to send all zone bypasses, resets, and force arm reports to
the receiver. The bypass report includes the zone number, zone name, and the
user name and number of the individual operating the system. Reports will only
be sent if
O/C User
in Communications is set
YES
for Receiver 1 or Receiver 2.
6.5
Schedule Change Reports
YES
allows the panel to send all permanent and temporary, primary and secondary
schedule changes to the receiver. The report includes the day, opening time,
closing time, and the user name and number of the individual making the change.
Schedule changes made through Remote Link™ are not sent to the printer or
Display Events. Reports will only be sent if
O/C User
in Communications is set
YES
for Receiver 1 or Receiver 2. XR200 default setting is
YES
; XR2400F is
NO
.
6.6
Code Change Reports
YES
allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user name and number added or
deleted and the user name and number of the individual making the change. Code
changes made through Remote Link™ are not sent to the printer or Display Events.
Reports will only be sent if
O/C User
in Communications is set YES for Receiver 1
or Receiver 2. XR200 default setting is
YES
; XR2400F is
NO
.
6.7
Access Keypads
Enter the keypad addresses that send door access reports to the receiver. A report
is sent with each door access made from the selected keypads. Keypads at
addresses not selected still operate the door strike relay but do not send door
access reports. The report includes the user name and number and the keypad
address used.
6.8
Ambush
YES
allows an ambush report to be sent anytime user code number 1 is entered at
a keypad.
NO
disables the ambush report and allows user number one to operate
the same as all other codes. If
YES
, you can program one Ambush code for each
partition in the system.
AMBUSH
NO
YES
ACS KEY: - - - - - - - -
CODE CHG NO
YES
SCHD CHG NO
YES
BYPASS NO
YES
NO YES DISARM
RESTORAL:
YES
ABORT
NO
YES
SYSTEM REPORTS
6 - SYSTEM REPORTS