Digital PRIORIS XL Server
Digital PRIORIS XL Server
Service Notes
Service Notes
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
87
87
P
R
I
O
R
I
S
X
L
Appendix A
Service Notes
This appendix contains the current
Service Notes
for the PRIORIS XL product line.
Known Server limitations.
♦
Do not install a 5¼-inch diskette drive in the top drive bay. EMI shielding might cause elecrical
shorts to the etch on the diskette drive’s circuit board.
♦
Due to the length of the IDE cable, make sure IDE drives are installed in drive bay slots 1 and 2.
Otherwise, the IDE cable will not reach the IDE drive’s connector.
♦
PCI IDE expansion boards will not work in the server.
♦
The time required to boot the server might increase when a DE422 network card is installed in a
server that uses a Pentium CPU module.
Recommended Tools
The following tools will be needed for servicing Digital PC systems. Note that test equipment must be in
calibration.
♦
Multimeter (4 1/2 digit)
♦
A philips screwdriver
♦
An antistatic wrist strap
Other Needed Materials
Cleaning agent should be an all purpose cleaner that is used in-house.
Required Special Tools.
None.