Beep Codes for Nonfatal Errors
The table below lists the beep codes when it encounters a nonfatal error. This table lists nonfatal errors that
do not lock up the computer. Fatal errors that lock up the computer are listed in a separate table.
Beep Code
Error Message
1-4-4
Software NMI port test in progress
3-3-4
Screen memory failure
3-4-1
Screen initialization failure
3-4-2
Screen retrace failure
Server Troubleshooting
Problem
Possible Cause
Action
No response
when the server
is turned on
Main logic board failed.
Main logic board jumpers
incorrectly set.
CPU module has failed.
CPU module jumpers
incorrectly set.
Replace Main logic board.
Set all appropriate jumpers
Replace Main logic board.
Make sure the jumpers are correctly set.
Power is on, but
there is no
screen display
Brightness and contrast controls
are not correctly set.
Monitor cable is incorrectly
installed.
Incorrect VGA drivers installed.
Video controller has failed.
Adjust the brightness and contrast controls.
Check all monitor connections.
Install the correct VGA drivers.
Replace Video controller.
Server operates
incorrectly after
installing
optional
expansion
board
Expansion board installed
incorrectly.
Did not run SCU to configure
expansion board after
installation.
Expansion board has failed.
Remove expansion board and reinstall.
Run the SCU to properly configure expansion
board.
.
Remove expansion board and reboot.
If server boots without errors, replace expansion
board.