Chapter 9: Using Digi 002 as a Stand-Alone Mixer
99
Digital Input Format
You can set Digi 002 to receive S/PDIF input at
the RCA Input connector or the Optical Input
port on the back panel of Digi 002. See “Digital
Audio Connections” on page 63 for details on
S/PDIF input format.
In Stand-alone mode, the RCA and Optical ports
accept S/PDIF signals at sample rates up to
48 kHz.
To change the digital input format for Inputs 5–6:
1
In Stand-alone mode, press the Utility (F1)
switch.
2
Press the illuminated Channel Select switch
under Pref.
3
Press the illuminated Channel Select switch
under SPDF (S/PDIF).
4
Press the illuminated Channel Select switch
repeatedly to toggle the digital format to RCA or
Optical.
5
Press the Escape (Esc) switch to exit SPDF pref-
erences.
6
Press the far right-hand Channel Select switch
to save the preference settings.
7
Press the Escape (Esc) switch twice to exit Util-
ity mode.
Digital Clock Source
When you connect an external digital source,
you can set Digi 002 to synchronize to external
Word Clock (the clock signal coming from the
device) or internal Word Clock (generated by
Digi 002). In most cases, such as with DAT
decks, you will use external clock.
To change the clock source for the digital inputs
on Inputs 5–6:
1
In Stand-alone mode, press the Utility (F1)
switch.
2
Press the illuminated Channel Select switch
under Pref.
3
Press the illuminated Channel Select switch
under WClk (Word Clock).
4
Press the illuminated Channel Select switch
repeatedly to toggle the clock source to Internal
or S/PDIF (external).
5
Press the Escape switch to exit SPDF prefer-
ences.
6
Press the far right-hand Channel Select switch
to save the preference settings.
7
Press the Escape (Esc) switch twice to exit Util-
ity mode.
When the Word Clock source is set to S/PDIF
(external), the Sample Rate indicator flashes to
indicate that no clock signal is present, or that
Digi 002 is not receiving valid clock signal. The
Sample Rate indicator lights solid to indicate
Digi 002 is receiving valid clock signal.
Digital input connectors (back panel)
Only one S/PDIF input pair can be used at a
time. For example, if you use the optical in-
put for S/PDIF data, you cannot use the
RCA inputs.
S / PDIF
IN
OUT
OPTICAL
MIDI OUT 1
MIDI OUT 2
IN
OUT
964530300294856
SERIAL NUMBER
RCA S/PDIF
Input
Optical
Input port
Summary of Contents for Digi 002
Page 28: ...Getting Started with Digi 002 Digi 002 Rack 20 ...
Page 54: ...Getting Started with Digi 002 Digi 002 Rack 46 ...
Page 58: ...Getting Started with Digi 002 Digi 002 Rack 50 ...
Page 76: ...Getting Started with Digi 002 Digi 002 Rack 68 ...
Page 124: ...Getting Started with Digi 002 Digi 002 Rack 116 ...
Page 128: ...Getting Started with Digi 002 Digi 002 Rack 120 ...
Page 136: ...Getting Started with Digi 002 Digi 002 Rack 128 ...
Page 148: ...Getting Started with Digi 002 Digi 002 Rack 140 ...