7-5 General specifications
Voltage class
200V
400V
1. Engine
Perkins, type
2806A
No-load speed (50/60Hz), approx………….min
-1
1560 / 1870 (Droop)
1500 / 1800 (Isochronous)
Load speed (50/60Hz), approx……………..min
-1
1500 / 1800
Electrical system……………………………..V
24
Batteries:
• Number
2
• Voltage……………………………..……....V
24
• Capacity…………………………………..
210H52×2
Oil circuit capacity…………………………....
ℓ
62
Cooling circuit capacity……………………...
ℓ
61
Fuel tank capacity, approx…...…………......
ℓ
490 (Optional opparatus)
2. Generator
Type…………………………………………… DF-6600P
Rated output 50/60Hz…………………..…….kVA
550 / 600
Voltage (range), line-to-neutral
50/60Hz…………………………………………...V
115 / 127 230 / 254
Voltage (range), line-to-line
50/60Hz…………………………………………...V
200 / 220
400 / 440
Frequency…………………………………...Hz
50 / 60
Speed (50/60Hz)…………………………min
-1
1500 / 1800
Power factor…………………………………....
0.8
Number of phases……………………………..
3 phases
Winding connection………………………..…..
star
Temperature specification………….………°C