7 - 2
Modulon DPH Series
7.1 LCD Display Hierarchy
MEASUREMENT
UPS-1.1
SETUP
MAINTENANCE
EVENT LOG
LOG IN
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 3)
(Level 1)
(Level 1)
(Level 1)
(Level 1)
(Level 1)
(Level 1)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
Power Flow
System Status
Main Input
Bypass Setting
Warning
Historical Event
Statistics
Test
Clear
Advanced
Diagnosis
Version & S/N
Mode Setting
Output Setting
Battery & Charging Setting
Parallel Setting
Dry Contact Setting
General Setting
IP Setting
Control
(Level 2)
EMS Setting
Bypass Input
Inverter Output
Power Module
Summary
UPS Output
Battery Status
(Level 2)
(Level 2)
EMS
Summary
Log-in ID:
User
Log-in ID:
Administrator
Input
Main Voltage
Bypass Voltage
Output
Frequency
Voltage
Current
Load
Output Power
Battery
Runtime Remaining
Voltage
Charge Current
(Discharge Current)
EMS
Temperature
Humidity
DI1 ~ DI4
SYSTEM
STS Temp. (°C)
Battery Temp. (°C)
Fan Speed (rpm)
POWER MODULE
INV Temp. (°C)
PFC Temp. (°C)
S/N
System
Touch Panel
Power Module #
MAIN
Parallel Communication Card #n_ MCU/ FPGA
System Control Card_ MCU/ FPGA
Touch Panel _ MCU
INV
Power Module #_MCU / FPGA
PFC
Power Module #_MCU / FPGA
MFC
MCU
Phase Voltage (V)
Line Voltage (V)
Current (A)
Frequency (Hz)
Kilowatt-Hour (kWH)
Bypass Frequency Range/
Bypass Voltage (Max)/ Bypass Voltage (Min)/
ECO Voltage Range (±%)
Warning
Historical Event
In Battery Mode
Battery Mode Duration
In Bypass Mode
Bypass Mode Duration
Operation Time
Manual Battery Test
Clear Statistics
Clear Historical Event
Clear Battery Test Result
Clear Kilowatt Hour (kWh)
On-Line/ Green/ ECO/ Energy Recycle/
Frequency Conversion
Voltage (V)/ Voltage Compensation (V)/
Frequency (Hz)/ Slew Rate (Hz/s)/
PM Redundancy (V)/
Async Transfer Time (ms)/
Module Sequential Start (s)/
System Sequential Start (s)
Battery Type/ Battery Rating Voltage/
Battery Strings/ Battery Low Warning/
Battery Cut Off Voltage/ Capacity/
Float Charge Voltage/
Equalized Charge Voltage (Restore Voltage ) /
Charge Current (Max)/
Auto Equalized Charge/
Auto Equalized Charge Interval/
Equalized Charge Time/
Battery Test Fail Voltage/
Battery Test Duration/
Auto Battery Test Interval/
Low Temperature Alarm/
High Temperature Alarm/
Installation Date/ Next Replacement Date
Parallel Group ID/ Parallel ID/
Common Battery
Phase Voltage (V)
Line Voltage (V)
Frequency (Hz)
Phase Voltage (V)
Line Voltage (V)
Current (A)
Frequency (Hz)
Phase Voltage (V)
Current (A)
DC BUS Voltage
PM A/D
PM D/D
Phase Voltage (V)
Line Voltage (V)
Current (A)
Frequency (Hz)
Load (%)
Apparent Power (kVA)
Active Power (kW)
Power Factor
Status/ Voltage (V)/
Current (A)/
Remaining Capacity (%)/
Remaining Time (mins)/
Estimated Recharging
Time (mins)/ Test Result/
Battery Temp. #1 (°C)/
Battery Temp. #2 (°C)/
Battery Temp. #3 (°C)/
Battery Temp. #4 (°C)/
Charge Voltage
of PM# (V) /
Charge Current
of PM# (A) /
String Voltage /
String Current /
Batt. Module SOH /
Cell Volt. (V) /
Cell Temp. (°C)
INPUT DRY CONTACT: 1 ~ 4
OUTPUT DRY CONTACT: 1 ~ 6
DHCP Client/ IP Address/ Subnet Mask/
Gateway IP/ DNS 1 IP/ DNS 2 IP/
Search Domain/ Host Name
Buzzer/ Reset Module / Reset System /
Force Equalized Charge /
Force Bypass to Inverter
Date/ Time
Date Format/ Date/ Time
Screen
Screen Brightness/ Screen Sleep (after)
User
Language/ Admin Password /
MODBUS ID / Baud Rate /
On/ Off Button Access
Dust Filter
Dust Filter Installation/
Dust Filter Installation Date/
Dust Filter Replacement Date
MFC
MODBUS ID/ MODBUS Baud Rate
Temperature
Humidity
DI1 ~ DI4
(Level 3)
(Level 2)
BMS
String Voltage /
String Current /
Ambient Temperature (°C) /
Cell Volt. (V) /
&HOO,5Pȍ
(Level 2)
(Level 3)
BMS Setting
Cell Voltage (V) /
String Voltage (V) /
Ambient Temperature (°C)
SENSOR
Temperature/ Humidity
INPUT CONTACT: 1 ~ 4
NO/ NC/ Event Type
*
1
*
2
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
3
*
3
*
1
*
1
*
1
*
1
*
1
*
1
*
2
*
2
*
2
*
2
*
2
*
4
*
5
*
6
*
2
*
1
*
2
*
1
*
1
*
1
(Figure 7-1: LCD Display Hierarchy)
Summary of Contents for Modulon DPH series
Page 26: ......
Page 58: ......
Page 168: ......
Page 237: ...8 1 8 Optional Accessories 8 Optional Accessories...
Page 240: ......
Page 241: ...9 1 9 Maintenance Maintenance 9...
Page 243: ...A1 1 Appendix 1 7HFKQLFDO 6SHFL FDWLRQV Technical 6SHFL FDWLRQV A1 A1...
Page 246: ......
Page 247: ...A2 1 Appendix 2 Warranty Warranty A2 A2...
Page 250: ......