66
PC Software - HH2Read
Moisture Meter User Manual 4.0
Tools Menu
From this menu you can select
Debug.
Install Menu
Use this menu to install sensor tables. There are two types:
Profile Probes and ThetaProbes have analogue outputs.
Linearisation tables
, with
filenames ending in ".Lin" are provided for the HH2 to convert the analogue mV
output into readings. Tables are permanently installed in the HH2 for use by all
SM200, ML1, ML2, PR1 and PR2 probes.
WET sensors have digital outputs. Unique
calibrations tables
are provided on disk
for each individual sensor, with file names ending in ".Cal". Only one digital sensor
can be installed at any one time.
On one field trip you can read many SM200, ML1, ML2, PR1 & PR2 probes, but you
can only read one WET.
Install, Linearisation Table
Options: SM200,, ML1, ML2, PR1, PR2, PR-Special.
Linearisation tables for all these devices are permanently installed in the HH2
microprocessor. These are not lost in the event of battery failure.
Only install new tables to the HH2 if you wish to replace the default tables by your
own custom tables - e.g. for unusual soils.
1. Connect your HH2 to your PC as described on page 61.
2. Select a device e.g.
Install, Linearisation Table, PR2
to display a Windows
Open
dialog.
3. Select the required table e.g.PR2.Lin.
The table will be parsed for correctness and if acceptable, installed.
Once installed, the Meter will be able to display readings for that device (once
selected e.g. using Options, Device, PR2).
Note: Tables must conform strictly to the format, described below under Linearisation
Tables.
Copies of the default factory set linearisation tables are supplied as separate files on
the HH2Read software disk, as follows
SM200.LIN
ML1.LIN
ML2.LIN
PR1.LIN
PR2.LIN
PR-SPECIAL.LIN
See also: Linearisation Tables Format on page 74.
Note: The file PR-SPECIAL.LIN is just a copy of the PR1 table. In the HH2 the PR-
SPECIAL option is provided as a placeholder for you to add your own, custom Profile
Probe sensor table. (Some PR1 users found this useful as a work-around for
Summary of Contents for HH2
Page 1: ...User Manual for the Moisture Meter type HH2 Delta T Devices Ltd Version 4 0 1 ...
Page 17: ...10 Navigating Options and Readings Moisture Meter User Manual 4 0 ...
Page 25: ...18 SM200 and ThetaProbes Moisture Meter User Manual 4 0 ...
Page 35: ...28 Profile Probes Moisture Meter User Manual 4 0 ...
Page 45: ...38 Profile Probes Moisture Meter User Manual 4 0 ...
Page 57: ...50 WET Sensor Moisture Meter User Manual 4 0 ...
Page 59: ...52 Equitensiometers Moisture Meter User Manual 4 0 ...