Chapter 4 Parameters
|
Revision Dec. 2008, 04VE, SW V2.05
4-89
bit3
MO2
bit2
MO1
bit1
RA
bit0
MRA
Pr02-15
0 0 0 1
1
0 0 1 0
2
0 0 1 1
3
0 1 0 0
4
0 1 0 1
5
0 1 1 0
6
0 1 1 1
7
1 0 0 0
8
1 0 0 1
9
1 0 1 0 10
1 0 1 1 11
1 1 0 0 12
1 1 0 1 13
1 1 1 0 14
1 1 1 1 15
02-16
Terminal Count Value
Unit:1
Control
mode
VF VFPG SVC
FOCPG TQCPG
Factory setting: 0
Settings
0 ~ 65535
The counter trigger can be set by the multi-function terminal MI6 (set Pr.02-06 to 23). Upon
completion of counting, the specified output terminal will be activated (Pr.02-11 to Pr.02-14 is
set to 17).
When the display shows c5555, the drive has counted 5,555 times. If display shows c5555
•
, it
means that real counter value is between 55,550 to 55,559.
02-17
Preliminary Count Value
Unit:1
Control
mode
VF VFPG SVC
FOCPG TQCPG
Factory setting: 0
Settings
0 ~ 65535
When the counter value reaches this value, the corresponding multi-function output terminal
will be activated, provided one of Pr. 02-11 to 02-14 set to 18 (Preliminary Count Value
Setting). This parameter can be used for the end of the counting to make the drive runs from
the low speed to stop.
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Summary of Contents for VFD-VE
Page 1: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 2: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 3: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 39: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...