Chapter 4 Parameters
|
Revision Dec. 2008, 04VE, SW V2.05
4-19
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQCPG
08-31
Reserved
08-32
Proportional Gain 2 of
Tension PID P
0.0~1000.0 50.0
○
○
○
○
08-33
Integral Time 2 of Tension
PID I
0.00~500.00 sec
1.00
○
○
○
○
08-34 Reserved
08-35
PID/Line Speed Output
Status
0: Positive output
1: Negative output
0
○
○
○
○
08-36
Tension/Line Speed PID
Output Limit
0~100.00% 20.00
○
○
○
○
08-37
Source of Line Speed
Input Command
0: Disable
1: Analog input (Pr. 03-00~03-02 is set to 12 line speed)
2: RS-485 communication setting (Pr.08-41)
3: Pulse input (Pr.08-40)
4: DFM-DCM pulse input (Pr.02-18)
0
○
○
○
○
○
08-38
Max. Line Speed
0.0~3000.0m/min
1000.0
○
○
○
○
○
08-39
Min. Line Speed
0.0~3000.0m/min
0.0
○
○
○
○
○
08-40
Pulse Number for Each
Meter
0.0~6000.0 pulse/m
0.0
○
○
○
○
○
08-41
Current Line Speed
0.0~3000.0m/min
0.0
○
○
○
○
○
08-42
Source of Reel Diameter
0: Calculated by line speed
1: Calculated by integrating thickness (encoder is on
reel shaft)(Pr.08-49~51, Pr.10-15)
2: Calculated by integrating thickness (encoder is on
motor)(Pr.08-23~08-24, 08-50~08-51, 10-00~10-01)
3: Calculated by analog input (Pr.03-00~03-02 is set to
13)
0
○
○
○
○
○
08-43
Max. Reel Diameter
1.0~6000.0mm
6000.0
○
○
○
○
○
08-44
Empty Reel Diameter
1.0~6000.0mm
1.0
○
○
○
○
○
08-45
Source of Initial Reel
Diameter
0: RS-485 communication setting (Pr.08-46)
1: Analog input (Pr.03-00-Pr.03-02 is set to 13)
0
○
○
○
○
○
08-46
Initial Reel Diameter
0.0~6000.0mm
1.0
○
○
○
○
○
08-47
Initial Reel Diameter 1
0.0~6000.0mm
1.0
○
○
○
○
○
08-48
Initial Reel Diameter 2
0.0~6000.0mm
1.0
○
○
○
○
○
08-49
Number of Pulse per
Revolution
1~10000ppr 1
○
○
○
○
○
08-50
Coil Number for Each
Layer
0.001~60.000mm 1.000
○
○
○
○
○
08-51
Material Thickness
0.001~60.000mm
1.000
○
○
○
○
○
08-52
Filter Time of Reel
Diameter
0.00 to 100.00 seconds
1.00
○
○
○
○
○
08-53
Auto Compensation of
Reel Diameter
0: Disable
1: Enable
1.00
○
○
○
○
○
08-54
Current Reel Diameter
1.0~6000.0mm
1.0
○
○
○
○
○
08-55
Smart Start Function
0: Disable
1: Enable
2: In unwind mode, rewind in reverse direction
1
○
○
○
○
08-56
Switch Level for Smart
Start and PID function
0.0~100.0% (according to Pr.08-26)
15.0
○
○
○
○
08-57
Frequency for Smart Start 0.00~600.00Hz
2.00
○
○
○
○
08-58
Accel. Time for Smart Start 0.01~600.00 seconds
3.00
○
○
○
○
08-59
Broken Belt Detection
0: Disable
1: Enable
0
○
○
○
○
08-60
Min. Line Speed of Broken
Belt Detection
0.0~3000.0m/min 0.0
○
○
○
○
08-61
Allowance Difference of
Reel Diameter of Broken
Belt Detection
1.0~6000.0mm 100.0
○
○
○
○
08-62
Detection Time of Broken
Belt
0.00~100.00 sec
1.00
○
○
○
○
08-63
Allowance Error Level of
Tension/Line Speed PID
Feedback
0~100% 100
○
○
○
○
08-64
Allowance Error Detection
Time of Tension/Line
Speed PID Feedback
0.0~10.0 sec
0.5
○
○
○
○
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Summary of Contents for VFD-VE
Page 1: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 2: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 3: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 39: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...