Chapter 4 Parameters
|
4-68
Revision Dec. 2008, 04VE, SW V2.05
Frequency
1st/4th Acceleration/Deceleration Switching
01-23
4th Acceleration Time
4th Deceleration
Time
1st Acceleration
Time
1st Deceleration
Time
1st/4th
Acceleration
/Deceleration
Freq.
01-24
S-curve for Acceleration Departure Time 1
Unit: 0.1/0.01
01-25
S-curve for Acceleration Arrival Time 2
Unit: 0.1/0.01
01-26
S-curve for Deceleration Departure Time 1
Unit: 0.1/0.01
01-27
S-curve for Deceleration Arrival Time 2
Unit: 0.1/0.01
Control
mode
VF VFPG SVC
FOCPG
Factory Setting: 0.2/0.0
Settings
0.00~25.00 sec /0.00~250.0 sec
It is used to give the smoothest transition between speed changes. The accel./decel. curve
can adjust the S-curve of the accel./decel. When it is enabled, the drive will have different
accel./decel. curve by the accel./decel. time.
The S-curve function is disabled when accel./decel. time is set to 0.
When the selected accel. time
≥
Pr.01-24 and Pr.01-25,
The Actual Accel. Time = selected accel. Time + (Pr.01-24 + Pr.01-25)/2
When the selected decel. time
≥
Pr.01-26 and Pr.01-27,
The Actual Decel. Time = selected decel. Time + (Pr.01-26 + Pr.01-27)/2
01-24
01-25
01-26
01-27
Frequency
Time
01-28
Skip Frequency 1 (upper limit)
Unit: 0.01
01-29
Skip Frequency 1 (lower limit)
Unit: 0.01
01-30
Skip Frequency 2 (upper limit)
Unit: 0.01
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Summary of Contents for VFD-VE
Page 1: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 2: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 3: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Page 39: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...