• You cannot configure a source port channel or source VLAN in a source session if the port channel or
VLAN has a member port that is configured as a destination port in a remote-port mirroring session.
• A destination port for remote port mirroring cannot be used as a source port, including the session in
which the port functions as the destination port.
• A destination port cannot be used in any spanning tree instance.
• The reserved VLAN used to transport mirrored traffic must be a L2 VLAN. L3 VLANs are not supported.
• On a source switch on which you configure source ports for remote port mirroring, you can add only
one port to the dedicated RPM VLAN which is used to transport mirrored traffic. You can configure
multiple ports for the dedicated RPM VLAN on intermediate and destination switches.
Displaying Remote-Port Mirroring Configurations
To display the current configuration of remote port mirroring for a specified session, enter the
show
config
command in
MONITOR SESSION
configuration mode.
Dell(conf-mon-sess-2)#show config
!
monitor session 2 type rpm
source fortyGigE 1/32 destination remote-vlan 300 direction rx
source Port-channel 10 destination remote-vlan 300 direction rx
no disable
To display the currently configured source and destination sessions for remote port mirroring on a
switch, enter the
show monitor session
command in
EXEC
Privilege mode.
Dell(conf)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
1 remote-vlan 100 Fo 1/32 N/A N/A N/A N/A
1 remote-vlan 100 Po 100 N/A N/A N/A N/A
2 Fo 1/4 remote-vlan 300 rx Port N/A N/A
2 Po 10 remote-vlan 300 rx Port N/A N/A
To display the current configuration of the reserved VLAN, enter the
show vlan
command.
Dell#show vlan
Codes: * - Default VLAN, G - GVRP VLANs, R - Remote Port Mirroring VLANs, P -
Primary, C - Community, I - Isolated
O - Openflow
Q: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
o - OpenFlow untagged, O - OpenFlow tagged
G - GVRP tagged, M - Vlan-stack
i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged
NUM Status Description Q Ports
* 1 Inactive
R 100 Active T Fo 1/20
R 300 Active T Fo 1/24
Configuring the Sample Remote Port Mirroring
Remote port mirroring requires a source session (monitored ports on different source switches), a
reserved tagged VLAN for transporting mirrored traffic (configured on source, intermediate, and
686
Port Monitoring
Summary of Contents for S6000-ON
Page 1: ...Dell Configuration Guide for the S6000 ON System 9 9 0 0 ...
Page 557: ...Figure 80 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 557 ...
Page 562: ...Figure 83 MSDP Default Peer Scenario 1 562 Multicast Source Discovery Protocol MSDP ...
Page 563: ...Figure 84 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 563 ...
Page 564: ...Figure 85 MSDP Default Peer Scenario 3 564 Multicast Source Discovery Protocol MSDP ...
Page 665: ...Policy based Routing PBR 665 ...
Page 818: ...Figure 110 Single and Double Tag TPID Match 818 Service Provider Bridging ...
Page 819: ...Figure 111 Single and Double Tag First byte TPID Match Service Provider Bridging 819 ...
Page 995: ...Figure 140 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 995 ...