![Dell S6000-ON Configuration Manual Download Page 413](http://html.mh-extra.com/html/dell/s6000-on/s6000-on_configuration-manual_84557413.webp)
Example of the
negotiation auto
Command
Dell(conf)# int tengigabitethernet 1/1/1
Dell(conf-if-te-1/1/1)#neg auto
Dell(conf-if-te-1/1/1-autoneg)# ?
end Exit from configuration mode
exit Exit from autoneg configuration mode
mode Specify autoneg mode
no Negate a command or set its defaults
show Show autoneg configuration information
Dell(conf-if-te-1/1/1-autoneg)#
mode ?
forced-master Force port to master mode
forced-slave Force port to slave mode
Dell(conf-if-te-1/1/1-autoneg)#
For details about the
speed
,
duplex
, and
negotiation auto
commands, refer to the
Interfaces
chapter of the
Dell Networking OS Command Reference Guide
.
Adjusting the Keepalive Timer
To change the time interval between keepalive messages on the interfaces, use the
keepalive
command. The interface sends keepalive messages to itself to test network connectivity on the interface.
To change the default time interval between keepalive messages, use the following command.
• Change the default interval between keepalive messages.
INTERFACE mode
keepalive [
seconds
]
• View the new setting.
INTERFACE mode
show config
View Advanced Interface Information
The following options have been implemented for the
show [ip | running-config] interfaces
commands for (only) stack-unit interfaces.
When you use the
configured
keyword, only interfaces that have non-default configurations are
displayed. Dummy stack-unit interfaces (created with the
stack-unit
command) are treated like any
other physical interface.
Examples of the
show
Commands
The following example lists the possible
show
commands that have the configured keyword available:
Dell#show interfaces configured
Dell#show interfaces stack-unit 1 configured
Dell#show interfaces tengigabitEthernet 1 configured
Dell#show ip interface configured
Dell#show ip interface stack-unit 1 configured
Dell#show ip interface tengigabitEthernet 1 configured
Dell#show ip interface br configured
Dell#show ip interface br stack-unit 1 configured
Dell#show ip interface br tengigabitEthernet 1 configured
Dell#show running-config interfaces configured
Dell#show running-config interface tengigabitEthernet 1 configured
In EXEC mode, the
show interfaces switchport
command displays only interfaces in Layer 2 mode
and their relevant configuration information. The
show interfaces switchport
command displays
Interfaces
413
Summary of Contents for S6000-ON
Page 1: ...Dell Configuration Guide for the S6000 ON System 9 9 0 0 ...
Page 557: ...Figure 80 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 557 ...
Page 562: ...Figure 83 MSDP Default Peer Scenario 1 562 Multicast Source Discovery Protocol MSDP ...
Page 563: ...Figure 84 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 563 ...
Page 564: ...Figure 85 MSDP Default Peer Scenario 3 564 Multicast Source Discovery Protocol MSDP ...
Page 665: ...Policy based Routing PBR 665 ...
Page 818: ...Figure 110 Single and Double Tag TPID Match 818 Service Provider Bridging ...
Page 819: ...Figure 111 Single and Double Tag First byte TPID Match Service Provider Bridging 819 ...
Page 995: ...Figure 140 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 995 ...