About Your System
31
PCI BIOS failed to install
PCI device BIOS (Option ROM)
checksum failure is detected during
shadowing. Loose cables to expansion
card(s); faulty or improperly installed
expansion card.
Reseat the expansion cards. Ensure that
all appropriate cables are securely
connected to the expansion cards. If the
problem persists, see "Troubleshooting
Expansion Cards" on page 131.
Plug & Play Configuration
Error
Error encountered in initializing PCI
device; faulty system board.
Install the NVRAM_CLR jumper and
reboot the system. See Figure 6-1 for
jumper location. If the problem persists,
see "Troubleshooting Expansion Cards"
on page 131.
Read fault
Requested sector not found
The operating system cannot read
from the diskette or hard drive, the
system could not find a particular
sector on the disk, or the requested
sector is defective.
Replace the diskette. Ensure that the
diskette and hard drive cables are
properly connected. See
"Troubleshooting a USB Device" on
page 119, "Troubleshooting a Diskette
Drive" on page 126, or "Troubleshooting
a Hard Drive" on page 129 for the
appropriate drive(s) installed in your
system.
Remote configuration
update attempt failed
System unable to process Remote
Configuration request.
Retry Remote Configuration.
ROM bad checksum = address
Expansion card improperly installed or
faulty.
Reseat the expansion cards. Ensure that
all appropriate cables are securely
connected to the expansion cards. If the
problem persists, see "Troubleshooting
Expansion Cards" on page 131.
Sector not found
Seek error
Seek operation failed
Faulty diskette or hard drive.
See "Troubleshooting a Diskette Drive"
on page 126 or "Troubleshooting a Hard
Drive" on page 129 for the appropriate
drive(s) installed in your system.
Shutdown failure
Shutdown test failure.
See "Troubleshooting System Memory"
on page 124.
The amount of system
memory has changed
Memory has been added or removed
or a memory module may be faulty.
If memory has been added or removed,
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" on page 124.
Table 1-7.
System Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for POWER EDGE 2900
Page 34: ...34 About Your System ...
Page 48: ...48 Using the System Setup Program ...
Page 114: ...114 Installing System Components ...
Page 138: ...138 Running the System Diagnostics ...
Page 146: ...146 Jumpers and Connectors ...
Page 176: ...176 Glossary ...
Page 182: ...82 Index 182 Index ...