6
Create the vEthernet and vFC interfaces for booting on the Cisco Nexus 5548-B Switch and add
the vFC to the vSAN database. On the Cisco Nexus 5548-B Switch only, enter the following
commands:
interface Vethernet751
switchport mode trunk
switchport trunk allowed vlan 1,1501
bind interface Ethernet1/7 channel 4
interface vfc751
bind interface Vethernet751
switchport trunk allowed vsan 11
no shutdown
vsan database
vsan 11 interface vfc 751
Some operating system installations require only one active path to storage. If this is
the case, one of the paths can be shut down on the Cisco Nexus 5548UP Switch. For
example, on Cisco Nexus 5548-B, you can enter the following commands:
interface vfc 751
shutdown
7
After successful installation of the operating system, you can enable the interface with the
following commands:
interface vfc 751
no shutdown