2
Enable virtual network tagging (VNTag) for the port that connects to the server:
interface Ethernet 1/7
switchport mode vntag
3
Create the VLANs:
vlan 301
name PROD-VLAN-301
vlan 302
name BACKUP-VLAN-302
4
Create the vEthernet port-profile:
port-profile type vethernet PROD-VLAN-301
switchport access vlan 301
switchport mode access
state enabled
port-profile type vethernet BACKUP-VLAN-302
switchport access vlan 302
switchport mode access
state enabled
5
Create the vEthernet and vFC interfaces on the Cisco Nexus 5548-A Switch and add the VFC
interface to the vSAN database. On the Cisco Nexus 5548-A Switch only, enter the following
commands:
interface Vethernet750
switchport mode trunk
switchport trunk allowed vlan 1,1500
bind interface Ethernet1/7 channel 3
interface vfc750
bind interface Vethernet750
switchport trunk allowed vsan 10
no shutdown
vsan database
vsan 10 interface vfc 750
37
|
Managing compute resources