8
Click
Save Changes
.
9
Repeat these steps for FC1, except make sure the
Uplink Port
field is set to 1, the
Default
VLAN
field is set to 1501, and the
Channel Number
field is set to 4.
Power cycling the host and verifying the host virtual Fibre Channel
After configuring all the components, perform the following steps:
Procedure
1
Power cycle the host.
2
Log on to both Cisco Nexus 5548UP Switches and ensure the host’s virtual Fibre Channel (vFC)
interface is up. For example, you can use the command
show interface brief
. Additional
vEthernet interfaces do not appear until the operating system is loaded.
Adding virtualized servers: modifying boot options
To configure the boot options, perform the tasks in the following sections.
Configuring the boot table
To configure the boot table, perform the following steps:
Procedure
1
Log on to CIMC on the server. On the left pane, select
Inventory
>
Network
>
Adapters
>
vHBAs
.
2
Highlight
fc0
and select
Boot
>
Table
.
3
Select
Add
and enter the first target for SAN booting and LUN ID. Select
Add
>
Boot
>
Entry
.
4
Select
Add
and enter the second target for SAN booting and LUN ID. Select
Add Boot Entry
.
5
Select
Close
.
6
Repeat these steps for fc1.
Mapping to the ISO file and rebooting the server
To map the ISO file, perform the following tasks:
Procedure
1
Log on to CIMC on the server. On the left pane, select
Summary
.
2
Select
Launch KVM
>
Console.
3
On the
Virtual
>
Media
tab, select
Add
>
Image
.
29
|
Managing compute resources