2
Create the VLANs:
vlan 301
name PROD-VLAN-301
vlan 302
name BACKUP-VLAN-302
3
Create the vEthernet port-profile:
port-profile type vethernet PROD-VLAN-301
switchport access vlan 301
switchport mode access
state enabled
port-profile type vethernet BACKUP-VLAN-302
switchport access vlan 302
switchport mode access
state enabled
4
Create static vEthernet interfaces (on both Cisco Nexus 5548UP Switches) for the server's
vNICs.
Due to failover mode and static vETH interface creation, identical vETH interfaces
must be created on both Cisco Nexus 5548UP Switches.
5548-A
interface Vethernet700
inherit port-profile PROD-VLAN-301
bind interface Ethernet1/7 channel 1
interface Vethernet701
inherit port-profile BACKUP-VLAN-302
bind interface Ethernet1/7 channel 2
5548-B
interface Vethernet700
inherit port-profile PROD-VLAN-301
bind interface Ethernet1/7 channel 1
interface Vethernet701
inherit port-profile BACKUP-VLAN-302
bind interface Ethernet1/7 channel 2
5
Create the vEthernet and vFC interfaces on Cisco Nexus 5548-A and add the VFC interface to
the virtual storage area network (vSAN) database. On the Cisco Nexus 5548-A Switch only, enter
the following commands:
interface Vethernet750
switchport mode trunk
switchport trunk allowed vlan 1,1500
bind interface Ethernet1/7 channel 3
interface vfc750
bind interface Vethernet750
switchport trunk allowed vsan 10
no shutdown
vsan database
vsan 10 interface vfc 750
33
|