Dell EMC
VxBlock
™
and Vblock
®
Systems 240
Administration Guide
Document revision 1.4
January 2018
Page 1: ...Dell EMC VxBlock and Vblock Systems 240 Administration Guide Document revision 1 4 January 2018...
Page 2: ...oved VMware vSphere 5 5 December 2016 1 3 Added support for AMP 2 Cisco UCS M4 servers with VMware vSphere 5 5 Removed VLAN 118 from topics April 2016 1 2 Added support for VxBlock System 240 VMware v...
Page 3: ...nts 25 Enabling network interface virtualization on the converged network adapter 26 Configuring the management vNICs 26 Configuring the vSphere vMotion vNICs 26 Configuring the production vNICs 27 Co...
Page 4: ...ting a LUN 65 Creating a storage group 65 Adding a host to a storage group 66 Adding a LUN to a storage group 66 Monitoring a RAID group 67 Using VMware EVC with Cisco UCS rack servers 67 Creating X B...
Page 5: ...are vSphere 6 0 91 Managing VMware vSphere ESXi 6 0 92 Configuring the persistent scratch location vSphere 6 0 92 Configuring the firewall on VMware ESXi hosts vSphere 6 0 93 Configuring advanced sett...
Page 6: ...Modifying the QoS settings 122 Upgrading the VEM software 123 Troubleshooting the Cisco Nexus 1000V switch 123 Guidelines for backing up system configuration files 125 Backing up configuration files...
Page 7: ...ble for managing the Converged System including the system administrator and personnel responsible for remote management of the Converged System The document assumes that the person administering the...
Page 8: ...adding users or cabinet access cards refer to the VCE Intelligent Physical Infrastructure Appliance User Manual Refer to the management release certification matrix RCM to identify the recommended fi...
Page 9: ...cedure 1 Use a web browser to navigate to the CIMC Manager software on the server that you are upgrading a Type the CIMC IP address for the server in the address field of the browser b Type your usern...
Page 10: ...edure 1 Use a web browser to navigate to the CIMC Manager software on the server that you are upgrading a Type the CIMC IP address for the server in the address field of the browser b Type your userna...
Page 11: ...lect Create Virtual Drive from Unused Physical Drives If there are pre existing virtual drives delete them and proceed 4 Create one RAID 1 virtual drive using 49 percent of the available capacity of a...
Page 12: ...s drive is referenced throughout these instructions 2 Create the named devices and data subdirectories It is recommended that you create one set of empty subdirectories and then copy them to the other...
Page 13: ...ups on backup media Otherwise you will be unable or severely limited in the ability to manage or recover the Converged System You must perform configuration backups for these devices Cisco management...
Page 14: ...Procedure To restore a configuration file refer to the documentation provided with the vendor to restore the device Managing the Advanced Management Platform 14...
Page 15: ...must be deployed and accessible About this task Use the syslog server to facilitate the reporting of alerts and to help troubleshoot Procedure 1 From the Admin tab within CIMC click CIMC Log 2 From th...
Page 16: ...eld Type the name of the person responsible for the SNMP implementation This name or information can include up to 254 characters such as an email address or a name and telephone number System Locatio...
Page 17: ...t the adapter card If the server is powered on the resources of the selected adapter card appear in the tabbed menu below the Adapter Cards area 5 In the tabbed menu below the Adapter Cards area selec...
Page 18: ...elected adapter card appear in the tabbed menu below the Adapter Cards area 5 In the tabbed menu below the Adapter Cards area select the vNICs tab 6 In the Host Ethernet Interfaces area select a vNIC...
Page 19: ...ere is no default VLAN for this vNIC click None Otherwise click the second radio button and enter a VLAN ID between 1 and 4094 VLAN Mode To use VLAN trunking select TRUNK Otherwise select ACCESS Rate...
Page 20: ...If this option is selected the CPU sends large TCP packets to the hardware to be segmented This option might reduce CPU overhead and increase throughput rate If this option is not selected the CPU seg...
Page 21: ...cted RSS is enabled forIPv6 extensions If this option is not selected RSS is not enabled for IPv6 extensions Enable TCP IPv6 Extension RSS If this option is selected RSS is enabled for TCP transmissio...
Page 22: ...e following sections the server is connected to port Eth1 7 on both Cisco Nexus 5548UP Switches Your configuration may be different Related information Virtual server interface numbering standards see...
Page 23: ...Ns are trunked where necessary Procedure 1 To enable virtual network tag VNTag for the port that connects to the server on Cisco Nexus 5548UP switches A and B type the following commands in configurat...
Page 24: ...n bind interface Ethernet1 7 channel 6 interface Vethernet705 inherit port profile production bind interface Ethernet1 7 channel 8 interface Vethernet707 inherit port profile n1k_L3_control bind inter...
Page 25: ...CoE vFC Interface 5548 A 5548 B 5548 A 5548 B 5548 A 5548 B 5548 A 5548 B 5548 A 5548 B 5548 A 5548 B 5548 A 5548 B A 1 100 101 102 103 104 105 106 107 108 109 150 151 150 151 B 2 200 201 202 203 204...
Page 26: ...nt vNICs perform the following steps Procedure 1 Log on to CIMC on the server Select Inventory Network Adapters vNICS 2 On the vNIC tab select Eth0 and select Properties 3 Verify that the Uplink Port...
Page 27: ...Port field is set to 0 5 Select Trust Host CoS 6 In the Channel Number field enter 7 7 In the Port Profile field select production 8 Click Add vNIC 9 Repeat these steps for Eth5 except ensure the Upli...
Page 28: ...set to 0 6 Select Trust Host CoS 7 In the Channel Number field enter 11 8 In the Port Profile field select nfs 9 Click Add vNIC 10 Repeat these steps for Eth9 except ensure the Uplink Port field is se...
Page 29: ...rvers modifying boot options To configure the boot options perform the tasks in the following sections Configuring the boot table To configure the boot table perform the following steps Procedure 1 Lo...
Page 30: ...Boot Option 4 select the SP port to boot from fourth Press Enter 8 Press F10 to save and exit select Yes to confirm Press Enter 9 Continue with normal operating system installation procedures Adding a...
Page 31: ...Design Adapter FEX with Cisco Nexus 5500 Switches and Cisco Nexus 2232 Fabric Extenders Related information Bare metal host dynamically created interface numbering standards see page 39 Bare metal hos...
Page 32: ...all VLANs are trunked where necessary On Cisco Nexus 5548UP Switches A and B enter the following commands Procedure 1 Enter the following commands in configuration mode to enable virtual network taggi...
Page 33: ...1 bind interface Ethernet1 7 channel 1 interface Vethernet701 inherit port profile BACKUP VLAN 302 bind interface Ethernet1 7 channel 2 5548 B interface Vethernet700 inherit port profile PROD VLAN 301...
Page 34: ...llowed vsan 11 no shutdown vsan database vsan 11 interface vfc 751 Some operating system installations require only one active path to storage If this is the case one of the paths can be shut down on...
Page 35: ...1 F 6 600 600 601 601 650 651 650 651 G 7 700 700 701 701 750 751 750 751 H 8 800 800 801 801 850 851 850 851 I 9 900 900 901 901 950 951 950 951 J 10 1000 1000 1001 1001 1050 1051 1050 1051 K 11 1100...
Page 36: ...tches as shown in the following illustration Your configuration may be different On Cisco Nexus 5548UP Switches A and B enter the following commands Procedure 1 Enable the auto creation of the Cisco N...
Page 37: ...e vethernet BACKUP VLAN 302 switchport access vlan 302 switchport mode access state enabled 5 Create the vEthernet and vFC interfaces on the Cisco Nexus 5548 A Switch and add the VFC interface to the...
Page 38: ...11 interface vfc 751 Some operating system installations require only one active path to storage If this is the case one of the paths can be shut down on the Cisco Nexus 5548UP Switch For example on...
Page 39: ...768 950 951 950 951 J 10 32768 32768 32768 32768 1050 1051 1050 1051 K 11 32768 32768 32768 32768 1150 1151 1150 1151 L 12 32768 32768 32768 32768 1250 1251 1250 1251 Related information Bare metal ho...
Page 40: ...s set to 1 which ensures that in the event of a failure traffic fails over automatically to 5548 A l Clear the PXE Boot check box It should not be selected m Set the Port Profile to BACKUP VLAN 302 n...
Page 41: ...e f Repeat these steps for fc1 2 Map to the ISO file and reboot the server a Log on to CIMC on the server On the left pane select Summary b Select Launch KVM Console c On the Virtual Media tab select...
Page 42: ...ule TPM is a computer chip that securely stores artifacts such as measurements passwords certificates or encryption keys which are used to authenticate the Converged System The Cisco TPM provides auth...
Page 43: ...ber of supported VLANs and VSANs see the Configuration Limits section of the Cisco Nexus 5000 Series NX OS Software Configuration Guide The following table details the VLAN ranges VLAN numbers Range U...
Page 44: ...llocated VLAN the system returns an error message However if you enter a range of VLANs and one or more of the specified VLANs is outside the range of internally allocated VLANs the command takes effe...
Page 45: ...iguration is required Zones are contained in a VSAN Hard zoning cannot be disabled Name server queries are soft zoned Only active zone sets are distributed Unzoned devices cannot access each other A z...
Page 46: ...a server network adapter with an Ethernet port on the switch This allows the channel to connect a vNIC on the server with a vEthernet interface on the switch Packets on each channel are tagged with a...
Page 47: ...in the port profile are not passed to the server network adapter If the server network adapter is not connected to the switch it is still possible to configure the vNICs on the server However the por...
Page 48: ...m is loaded Refer to the documentation for your specific adapter for details The global configuration command no vethernet auto create stops the vEthernet interfaces from being automatically created I...
Page 49: ...e Cisco Virtual Machine Fabric Extender VM FEX which unifies virtual and physical networking into a single infrastructure It provides VM visibility from the physical network and a consistent network o...
Page 50: ...2 BD D6 5C 35 Disabled 0 fc1 20 00 00 22 BD D6 5C 36 Disabled 1 The following example displays the properties of a specified vHBA in detail Server chassis scope adapter 1 Server chassis adapter show h...
Page 51: ...to 10000 Mbps the default is off set order any 0 99 Relative order of this device for PCIe bus device number assignment the default is any set error detect timeout msec Error detect timeout value EDT...
Page 52: ...efault is 512 operations set max target luns count Maximum LUNs per target the maximum number of LUNs that the driver will discover This is usually an operating system platform limitation The range is...
Page 53: ...y that the first switch has not experienced a platform outage before upgrading the second switch Before you begin Obtain Console terminal access Management IP access A Cisco account to download any im...
Page 54: ...used 1351081984 bytes free 1650905088 bytes total 5 If there is not enough space type delete bootflash filename If you delete the active system or kickstart image do not reboot the switch 6 To copy t...
Page 55: ...1 1c bin 100 SUCCESS Extracting bios version from image bootflash n5000 uk9 5 0 2 N2 1 bin 100 SUCCESS Performing module support checks 100 SUCCESS Notifying services about system upgrade 100 SUCCESS...
Page 56: ...ing to following table Module Image Running Version New Version Upg Required 1 system 5 0 2 N2 1 5 0 3 N1 1c yes 1 kickstart 5 0 2 N2 1 5 0 3 N1 1c yes 1 bios v1 8 0 10 06 2010 v3 5 0 02 03 2011 yes 1...
Page 57: ...l Software BIOS version 3 5 0 loader version N A kickstart version 5 0 3 N1 1c system version 5 0 3 N1 1c power seq Module 1 version v3 0 Module 2 version v1 0 Module 3 version v2 0 uC version v1 1 0...
Page 58: ...n http www cisco com c en us td docs switches datacenter nexus3000 sw upgrade 7_x Cisco_n3k_Upgrade_Downgrade_7x html Cisco Nexus 9000 Series NX OS Software Upgrade and Downgrade Guide Managing networ...
Page 59: ...From the NAT Mode window type the required IP addresses and click Add IP The NAT Mode window does not appear when connecting from within the Converged System or when using the native IP addresses of...
Page 60: ...Storage Pool window select Pool for the Storage Pool Type type the name of the pool and select a RAID type 5 Under Disks click Manual for disk selection and click Select 6 From the Disk Selection wind...
Page 61: ...nfiguration Storage Pools 3 When the Pools window appears select the storage pool and click Expand 4 From the Expand Storage Pool window under Disks select Manual and click Select 5 When the Disk Sele...
Page 62: ...boot LUN About this task The information in this procedure is specific to environments or situations where Ionix UIM P is not used To provision a new service using Ionix UIM P refer to the Ionix Unif...
Page 63: ...te additional LUNs repeat this procedure or if you are finished click Cancel to exit 12 To verify that the LUN has been created from the LUNs menu look for the new LUN in the list Related information...
Page 64: ...w appears under the General tab select Pool for the Storage Pool Type and the RAID type Once the RAID type has been selected the storage pools of that RAID type appear 5 Select the storage pool to cre...
Page 65: ...roup Use this procedure to create a storage group on a storage array using Unisphere Procedure 1 Log on to Unisphere and select a storage array to create the storage group 2 Select Hosts Storage Group...
Page 66: ...connect the host and click Connect Hosts 4 From the Storage Group Properties window select the Hosts tab By default Show Hosts Not connected is selected Do not change this setting unless you want to...
Page 67: ...Select the LUNs tab and view the LUN Monitoring a RAID group Monitor a RAID group on a storage array using Unisphere Procedure 1 Log on to Unisphere and select the storage array to monitor 2 Select S...
Page 68: ...se features might not be enabled in the BIOS due to U S export rules To ensure complete and reliable vMotion compatibility when mixing rack types in a single cluster use Intel Xeon Core i7 EVC mode If...
Page 69: ...Creating X Blades Configuring Virtual Data Movers on VNX provides information on creating X Blades Refer to Configuring Virtual Data Movers on VNX 69 Creating X Blades...
Page 70: ...hick LUN STD fully allocated or thick VP Pool LUN or RG volume Do not use auto extend unless specifically requested by the customer The auto extended file system displays the maximum size of the file...
Page 71: ...nt point with the same name as the file system f Select the X Blade that you want to use g Click Apply 5 A message confirming the creation of the file system appears in the top of the window Click Can...
Page 72: ...ystem field select a file system and type a path b In the Host Access field type the IP addresses of the hosts that require access to the NFS export In this example all of the hosts in the 192 168 X X...
Page 73: ...In the Server field type the IP address of the NFS virtual interface of the X Blade where the NFS export exists b In the Folder field type the path of the NFS export c In the Datastore Name field type...
Page 74: ...t VM 2 Select Storage Shared Folders NFS 3 From the list of NFS exports right click the NFS export and select Delete 4 If a warning message appears indicating a problem with the website s security cer...
Page 75: ...mes STDs Thick LUNs on RAID groups slicing is permitted Do not thin a file system with a thin TDEV or Thin VP Pool LUN backend volume Only thin the file system with a thick volume on the backend A bac...
Page 76: ...duplication Enabled unless specifically requested by customer f From the Data Mover R W field select the X Blade on which the CIFS server resides If the CIFS server resides on a virtual X Blade select...
Page 77: ...with the website s security certificate click Continue to this website 5 When the Create CIFS Share window appears perform the following a From the Choose Data Mover field select the X Blade on which...
Page 78: ...t Create a new test directory to verify that you have read write privileges to this share Unmapping a CIFS share Use this procedure to disconnect a CIFS share Before you begin Verify that the share is...
Page 79: ...the CIFS share and select Delete 4 When Confirm Delete message appears click OK 5 To verify that that CIFS share was deleted select Storage Shared Folders CIFS From the list of shares verify that the...
Page 80: ...You might need to upgrade third party software prior to updating to the latest release of VMware ESXi Obtain the Release Certification Matrix and Release Notes with the version to which you want to u...
Page 81: ...options are set Apply NFS options before connecting any NFS share to the VMware vSphere ESXi hosts You can configure the settings on each host individually using the VMware vSphere client or run the V...
Page 82: ...osts Get VMHost Sort Name foreach esx in esxHosts Write Host Updating TCP and NFS advanced configuration Settings on esx Update TCP settings if Get VMHostAdvancedConfiguration VMHost esx Name Net Tcpi...
Page 83: ...tings window appears 5 Referring to the table at the top of Configuring advanced settings for VMware vSphere ESXi see page 81 restore the default values for the following parameters Disk UseDeviceRese...
Page 84: ...g to ESXi 6 5 from earlier versions of ESXi use this task to increase the SAN boot VMFS datatstore capacity for compute hosts Dell EMC recommended Boot LUN capacity for ESXi 6 5 to be increased to 15G...
Page 85: ...ew DWORD 32 bit Value 3 Type the value name TimeOutValue The name is case sensitive 4 Set the data type to REG_DWORD 5 Set the data to 190 decimal 6 Reboot the VM Setting up Java and Internet Explorer...
Page 86: ...t Site List which opens in the Exception Site List popup window 6 Add the URLs of web based applications For example https ip_address_of_web_based_application 7 Click OK to close the Exception Site Li...
Page 87: ...2034608 contains instructions to unlock a VMware vCenter SSO administrator account About this task For security purposes the VMware vCenter administrator account is locked after three failed log on a...
Page 88: ...click Edit 5 Make the required changes and click OK Managing VMware vCenter SSO lockout policies Modify the strict lockout policy of VMware vCenter SSO for VMware vSphere Procedure 1 Log on to the VMw...
Page 89: ...pted All users currently accessing this node temporarily lose connectivity If this node is a vCenter Server features such as DRS and vMotion will temporarily become unavailable If this node is a PSC s...
Page 90: ...based backup and restore In vSphere 6 5 the vCenter Server Appliance Management Interface is used to create a file based backup of the vCenter Server Appliance and Platform Services Controller Procedu...
Page 91: ...the VMware vSphere Availability Guide from the VMware vSphere 6 x Documentation Center 2 Review and resolve all validation and compliance checks needed to ensure fault tolerance is operational 3 Conf...
Page 92: ...re vSphere ESXi host Procedure 1 Connect to vCenter Server or the VMware vSphere ESXi host using the vSphere Client 2 Click the VMware vSphere ESXi host in the inventory select the Configuration tab h...
Page 93: ...ed with the Firewall section 4 Enable or confirm the following services for access through the firewall a Syslog b SSH Client c NTP Client d vCenter Update Manager 5 Click OK Configuring advanced sett...
Page 94: ...phere ESXi hosts Before you begin Ensure you have network access and administrative privileges to the VMware vSphere ESXi hosts Procedure 1 Within the vSphere client select the host 2 Select Time Conf...
Page 95: ...ry DNS server if it is not already specified 6 In the Alternate DNS server field enter the alternate DNS server if it is not already specified 7 Update the Hostname and Domain fields if necessary 8 Cl...
Page 96: ...tem coredump network set i ip_address_of_core_dump_collector on vCenter v vmk0 o 6500 esxcli server ip_address_of_esxi_host system coredump network set enable true From the VMware ESXi host type esxcl...
Page 97: ...iltering and marking policies Standard configuration settings must not be changed to ensure proper Converged System operation About this task Using the VMware vSphere Web Client only one distributed p...
Page 98: ...group only has one active uplink associated with vNIC2 fabric A The other uplink should be in standby mode Network failure detection Link status only Notify switches Yes Failback Yes Monitoring Netfl...
Page 99: ...ssions 3 On the VMware vSphere Web Client Home tab under Inventories click Networking 4 Right click DVSwitch01 A and select New Distribution Port Group 5 From the New Distributed Port Group wizard to...
Page 100: ...ck Next e From the Select network adapter tasks window deselect Manage physical adapters and verify that Manage VMKernel adapters is selected f Click Next g Select the VMware vSphere ESXi host and cli...
Page 101: ...ing URL https vCenterIP 9443 vsphere client You can also launch the VMware vSphere Web Client by selecting Start Menu All Programs VMware VMware vSphere Web Client The alternative launch method above...
Page 102: ...t You can also launch the VMware vSphere Web Client by selecting Start Menu All Programs VMware VMware vSphere Web Client The alternative launch method above does not apply to vSphere 6 5 2 Log on to...
Page 103: ...select NIC settings and change the MTU value from 1500 to 9000 8 Click OK 9 Repeat this procedure for each VMware vSphere ESXi host as needed Modifying CoS settings The CoS marking is leveraged as par...
Page 104: ...ic direction to Ingress The VMware vSphere 6 x Release Notes contain information about ingress and egress parameters e Select the green plus and select New IP Qualifier f From the Protocol drop down s...
Page 105: ...switch with the following criteria If migrating to a different VMware VDS Attach at least one VMNIC as an uplink for a new distributed or standard switch Create the distributed port groups with the s...
Page 106: ...on the distributed port group delete the distributed port group from the existing VMware VDS Before you begin Verify there is no port assignment connected to any of the distributed port group on any o...
Page 107: ...te vMotion all powered on VMs to a different VMware vSphere ESXi host to free up the ports on the VMware VDS VMs can still point to the same distributed port groups from a different VMware vSphere ESX...
Page 108: ...to a different distributed or standard switch About this task This procedure is not required if there are no powered on VMs on the distributed port group VMs connected to the distributed port group c...
Page 109: ...VMware vSphere SSOaccount or other administrative account with appropriate permissions 3 On the VMware vSphere Web Client Home tab under Inventories click Networking 4 Right click DVswitch01 A and se...
Page 110: ...here local user account VMware vSphere SSO account or other administrative account with appropriate permissions 3 On the VMware vSphere Web Client Home tab under Inventories select Hosts and Clusters...
Page 111: ...wizard perform the following a Select Remove hosts and click Next b Select Attached hosts c From the Select member hosts window select the VMware vSphere ESXi host to be deleted and click OK You can m...
Page 112: ...switch with the following criteria If migrating to a different VMware VDS Attach at least one VMNIC as an uplink for a new distributed or standard switch Create the distributed port groups with the s...
Page 113: ...Ms have been migrated from the VMware VDS Before you begin Verify that all VMs have been migrated off the VMware VDS Procedure 1 Open a browser and type the following URL https vCenterIP 9443 vsphere...
Page 114: ...write the existing dvSwitch currently in use Each feature is broken out by administrative procedures Exporting a backup of a VMware dvSwitch configuration Export the configuration of the VMware VDS dv...
Page 115: ...Web Client Home tab under Inventories click Networking 4 Right click Datacenter and select All vCenter Actions Import Distributed Switch 5 Click Browse to select Select a distributed switch backup fi...
Page 116: ...ick Browse to select Select a distributed switch backup file and click Next 7 Review the import settings and click Finish VMware VDS basic troubleshooting The VMware vSphere Networking Guide contains...
Page 117: ...ample purposes only Procedure 1 Log on to the Cisco Nexus 1000V VSM 2 To start the configuration type n1000v config t 3 To specify the port profile name type n1000v config port profile type vethernet...
Page 118: ...recommended refer to the Logical Configuration Guide When modifying the uplink port profile northbound traffic from the Cisco Nexus 1000V Switch through the Cisco Nexus 5548UP switches is affected Fo...
Page 119: ...switchport mode trunk switchport trunk allowed vlan 116 channel group auto mode on mac pinning no shutdown system vlan 116 state enabled For unified only port profile type ethernet NFS UPLINK vmware p...
Page 120: ...on to the VSM 2 Type the following commands configure terminal no port profile type ethernet PRODUCTION UPLINK copy run start end Modifying vEthernet data port profiles Modify data port profiles for...
Page 121: ...4 system vlan 117 or L3 vMotion vlan number service policy type qos input SET_COS_4 state enabled copy run start For Unified Systems port profile type vethernet VCESYS_ESX_NFS vmware port group switch...
Page 122: ...he interface that carries the control and packet VLAN traffic If the VSM VMs are not hosted on the VEM in an VMware vSphere ESXi host that it is managing for example the VSM VMs are hosted on separate...
Page 123: ...os SET_COS_6 class class default set cos 6 Upgrading the VEM software For instructions on performing the upgrade refer to Cisco Nexus 1000V VEM Software Installation and Upgrade Guide for your release...
Page 124: ...Related information Cisco Nexus 1000V Troubleshooting Guide Managing the Cisco Nexus 1000V Series Switch 124...
Page 125: ...stems About this task IPv4 addresses are supported on Vblock Systems and VxBlock Systems Before you begin TFTP service must be installed configured and active on the AMP or AMP 2 server where the conf...
Page 126: ...startup config tftp IP device config name_startup_ TIMESTAMP cfg SWITCH config job copy running config tftp IP device config name_running_ TIMESTAMP cfg SWITCH config job end SWITCH 4 To schedule the...
Page 127: ...rver Connection to server Established Copying Started TFTP put operation was successful 7 To save the configuration updates type SWITCH copy running config startup config 100 8 To verify the procedure...
Page 128: ...nto the file name when the tasks are executed It is recommended that a script be deployed that processes the files with the TIMESTAMP string present and transforms it into the date and time when the f...
Page 129: ...r log on credentials About this task Perform this backup process on a daily basis Frequency depends upon the client RPO Procedure 1 Connect to the client AMP environment jump server 2 From the jump se...
Page 130: ...ver Agent Jobs 8 To create a backup job right click Jobs and select New Job a Type a value in the Name field to correspond with the backup to be performed For example Daily Full backup master b In the...
Page 131: ...lect Quit the job reporting success You can optionally type a directory location and file name into the Output file field to capture script log messages For example I Backups master log h Click OK 10...
Page 132: ...ons a Type BAK file management as the job description b Select master for the Database field c For Command field use this text SQL Server Transact SQL script to perform backup file management Use this...
Page 133: ...of any software described in this publication requires an applicable software license Copyright 2015 2016 2018 Dell Inc or its subsidiaries All Rights Reserved Dell EMC and other trademarks are trade...