DESIGNER’S HANDBOOK 4189350049C EN
Page 174 of 206
When the wind direction is received every second from the wind sensor, the filter value 8 means that data is
averaged over the last 8 measurements or over 8 seconds.
11.14.3 The other input configuration parameters
The hex value 0x39F1:0x02 in the top line is the data index and sub-index used to distribute data on XDi-net, it is
only for information and cannot be changed from the menu.
In the last menu line, you can change or stop the distribution of this data type on XDi-net (CAN).
In this input configuration menu, it is also possible to manually set up the input channel, the talker ID and the
sentence. You should only set up or change those parameters if you know what you are doing.
It can however be useful in the situation where an NMEA sentence is not available when the auto scan and setup
process is performed during installation. Maybe the sensor is not added until later, but the sentence and input port
are known.
11.15 CAN bus changes via menu
The default CAN bus parameters is defined in the product profile you have selected during setup, and they can be
changed manually via the XDi installation menu.
Please note that relative wind speed and wind direction both by default have a filter
value. It often makes sense to filter harder on the wind direction than on wind speed.