DESIGNER’S HANDBOOK 4189350049C EN
Page 24 of 206
The fall-
back mode can be “Auto” or “Manual”.
In manual mode the fall-back source number (shown in the next line) will be locked as the input source.
Fall-back timeout
: This parameter defines the time to go before the active source is replaced by the next priority
source, after the active source has lost its data.
When a higher priority source reappears, it will automatically take over as source.
or
indicates if the source at present is providing input data or not.
Source priority:
It is possible to change the priority order from this menu. It is possible to give 2 fall-back sources
the same priority. In this case, reappearance of the other source with the same priority will not result in a source
shift.
Source name:
It is also possible to change the source name.
Be aware that the source name is often presented at the indicator to show which source is active and providing
data.
In the standard heading indicator, the names: GYRO 1, GYRO 2 and MAG. COMPASS is shown on the scale as
illustrated below.