4. Setting up the device
17
Release/lock analog output parameter,
Out.LE:
Analog output parameter can be locked or released for the user:
- At
En-oF
the initial or final value can be changed in operation mode.
- At
Out.EO
the output signal can be changed from e.g. 0-20mA to 4-20mA or 0-10VDC.
- At
ALL
analog output parameters are released.
- At
no
all analog output parameters are locked.
Master code,
A.Code
:
By entering
A.CodE
the device will be unlocked and all parameters are released.
User code
U.Code:
Via this code reduced sets of parameters can be set free. A change of the
U.CodE
can
be done via the correct input of the
A.CodE
(master code).
Parameterisation level
Menu level
Menu group level
4.3.3. Safety parameters
Menu level